MANUAL P/N 900000108 REV D
Reduced Air Flow –
Installation of the equipment in a rack should be such that the amount of air flow required
for safe operation of the equipment is not compromised.
Mechanical Loading –
Mounting of the equipment in the rack should be such that a hazardous condition is not
achieved due to uneven mechanical loading.
Circuit Overloading –
Consideration should be given to the connection of the equipment to the supply circuit
and the effect that overloading of the circuits might have on over-current protection
and supply wiring.
Reliable Earthing –
Reliable earthing of rack-mounted equipment should be maintained. Particular attention
should be given to supply connections other than direct connections to the J1 Connector
WARNING:
J1 output is not a Limited Power Source (LPS). All devices connected to
this connector must be listed by a National Recognized Testing Laboratory
(NRTL) and be provided with a suitable fire enclosure.