MANUAL P/N 900000108 REV D
35
5.1.5.3.2
Manual Mode Settings
The Manual Mode Settings consist of one combo box, the Settings. The Settings allows the user to
manually set the leap indicator setting used.
Table 6
describes the supported leap indicator settings
used.
DESCRIPTION
No warning
Last minute has 61 seconds
Last minute has 59 seconds
Alarm condition (clock not synchronized)
Table 6 Leap Indicator Settings
If the leap indicator setting is set to no warning, the ENTA automatically warns of an impending leap
second only if the internal GPS receiver is used as the synchronizing source.