4.7 Magnet Rack, adjustment
Before replacing the magnet rack in the printer, two adjustments must be checked.
The fi rst one is the distance between the support list and the pivot arms. This is the travelling distance
for the pivotarm. And it should be adjusted to about 0.8 mm using a feeler gauge. Adjust the nuts on
both ends of the magnet rack.
If the 0.8 mm feeler gauge goes in, and the 0.9 mm feeler gauge does not, consider the adjustment
OK.
Make sure that the nuts are thigth when you are done!