9
Installation
Phenolic Privacy Restroom Partitions, Floor-to-Ceiling — Series 700, — 69", 72" & 69"/72" Tall
Bradley •
HDWC-INSTR-045 Rev. A: ECO 20-14-002S
6/25/2021
Door Height
A.F.F.
Bracket Height
Dim "C"
69"
(1753)
9-1/2" ¹
(241)
68"
(1727)
Dim "C"
72"
(1829)
6-1/2"
(165)
71"
(1803)
Dim "C"
Dim "D"
72" (1829)
69" (1753)
6-1/2" (165)
9-1/2" (241) ¹
71" (1803)
68" (1727)
¹ ADA Stall
1
Layout Dimensions - Stirrup Brackets (Standard)
*
*
*
*
*
*
*
*
*
Pilaster Plumb Line
When installing the partition components, consult
the applicable Mills Partition submittal drawing
for compartment layout dimensions.
Pilaster Centerline:
Measure from the back
wall forward to the face of the compartment,
subtract 3/8" (10) and mark this location on
the floor ("A") . Mark the same measurement
on the opposite end of your layout ("A1")
and draw a straight line connecting both
marks .
For Freestanding (FS) Partitions:
Refer
to submittal drawings and determine the
approximate location of the outside panels .
Establish dimensions "A" and "A1" as
explained above .
A
Panel Centerline:
Measure the stall width across the
back wall and place a mark at the base of the rear wall
("B") . Repeat this step for each panel, starting each
measurement from the last panel centerline ("B1") .
B
Draw a plumb line on all walls from each pilaster
and panel centerline . From the highest point in
the room, measure 19" (483), 47" (1194), and
70" (1778) from the floor and place a mark on the
pilaster/panel plumb line . These marks represent
the hole centerline of the stirrup brackets . Use a
level to transfer that mark to all other plumb lines
("C") .
C
Panel
Plumb Line
70"
(1778)
47"
(1194)
19"
(483)
"C"
"C"
"C"
"C"
"C"
"C"
"C"
"C"
"C"
"B1"
"A1"
"B"
"A"
CL
CL
CL
CL
CL
CL
CL
CL
CL
CL
*
*
*
*
*
*
Panel
Plumb
Line
"C"
"C"
"C"
"A"
"B"
"B1"
"A1"
"D"
"D"
"D"
When installing the partition components, consult
the applicable Mills Partition submittal drawing for
compartment layout dimensions.
1a Layout Dimensions - Continuous Brackets (Optional)
Pilaster Centerline:
Measure from
the back wall forward to the face of the
compartment, subtract 3/8" (10 mm) and
mark this location on the floor ("A") . Mark
the same measurement on the opposite
end of your layout ("A1") and draw a
straight line connecting both marks .
For Freestanding (FS) Partitions:
Refer
to submittal drawings and determine
the approximate location of the outside
panels . Establish dimensions "A" and
"A1" as explained above .
A
Panel Centerline:
Measure the stall width across the
back wall and place a mark at the base of the rear wall
("B") . Repeat this step for each panel, starting each
measurement from the last panel centerline ("B1") .
B
Draw a plumb line on all walls from each pilaster and panel
centerline . From the highest point in the room, measure from the
floor and place a mark on the pilaster/panel plumb line for the
respective door height (see table) . Use a level to transfer that
mark to all other plumb lines ("C") . For ADA stalls, use "D" as a
reference point (see table) .
C