12
Phenolic Privacy Restroom Partitions, Floor-to-Ceiling — Series 700, — 69", 72" & 69"/72" Tall
Installation
6/25/2021
Bradley •
HDWC-INSTR-045 Rev. A: ECO 20-14-002S
4
Stirrup Brackets to Pilaster (Standard)
Refer to the submittal drawing to locate the split
dimension and layout location of each marked pilaster.
8' Ceiling:
Measure down from the top of the pilaster and
place a mark on the pilaster split centerline at the dimensions
shown for the respective bracket .
For ceiling heights other than 8':
add or subtract the
appropriate amount to the dimensions shown . For example, a
9' ceiling would add 12" (305) to each dimension .
A
Split
Split
47"
(1194)
24"
(610)
75"
(1905)
Place stirrup brackets at each established level line . Center
the bracket opening on the pilaster split centerline . Using the
bracket as a template, mark the hole locations on the pilaster .
Remove the bracket and drill a Ø15/64" pilot hole, 5/8" (16)
deep at each location .
B
Secure the stirrup brackets to the pilasters using the
#14 x 5/8" screws provided .
C
Pilaster shown is for reference only. Actual pilaster varies
depending on application.
CL
CL
4a Continuous Brackets to Pilaster (Optional)
Refer to the submittal drawing to locate the split
dimension and layout location of each marked pilaster.
8' Ceiling:
Measure down from the top of each
pilaster and place a mark on the pilaster split
centerline at dimensions "A" and "B" for the
respective bracket (see table) .
For ceiling heights other than 8':
add or subtract
the appropriate amount to the dimensions shown .
For example, a 9' ceiling would add 12" (305) to
each dimension .
A
Secure the continuous bracket to the pilasters
using the #14 x 5/8" screws provided .
C
Place the continuous bracket between each
established level line . Center the bracket opening
on the pilaster split centerline . Using the bracket
as a template, mark the hole locations on the
pilaster . Remove the bracket and drill a Ø15/64"
pilot hole, 5/8" (16) deep at each location .
B
Brackets are used as templates, but since the hole patterns
may be different, the brackets may not be interchangeable.
Refer to the
submittal drawing
for the correct
orientation
of the pilaster .
Pilaster shown is for reference only. Actual pilaster
varies depending on application.
Split
Split
"B"
Dim . "A"
Dim . "B"
69"
Pilaster
(ADA)
16-1/2"
(419)
84-1/2"
(2146)
72"
Pilaster
(Standard)
16-1/2"
(419)
87-1/2"
(2222)
CL
Refer to the
submittal drawing
for the correct
orientation
of the pilaster .
"A"
Bottom of
Bracket