23
Installation
Phenolic Privacy Restroom Partitions, Floor-to-Ceiling — Series 700, — 69", 72" & 69"/72" Tall
Bradley •
HDWC-INSTR-045 Rev. A: ECO 20-14-002S
6/25/2021
7
Pilaster Shoes
Using the L-bracket(s) as a template, drill a Ø15/64" pilot
hole into the pilaster, 5/8" (16) deep . Secure L-bracket(s) to
pilaster using the 1/4" x 5/8" screws provided .
A
Using the hole in the top shoe as a template, drill a Ø15/64"
hole through the pilaster . Secure the top shoe to the pilaster
using the 1/4" x 5/8" screws provided .
B
Using the hole in the bottom shoe as a template, drill a
Ø1/4" hole through the pilaster . Secure the pilaster to the
bottom shoe using the #10-24 x 1/2" barrel nut and
#10-24 x 3/4" shoulder screw provided .
C