20
Phenolic Privacy Restroom Partitions, Floor-to-Ceiling — Series 700, — 69", 72" & 69"/72" Tall
Installation
6/25/2021
Bradley •
HDWC-INSTR-045 Rev. A: ECO 20-14-002S
To establish level line, from the highest point in the room, measure 6" Ref. (152) from the floor. Use a level to transfer
this mark to the pilaster plumb line.
See Step 2 for instructions on mounting the stirrup brackets to a wall.
Wall
Specified Dimension
(Standard Gap 1" (25))
6" Ref .
(152)
Pilaster Plumb Line
Floor
Pilasters at Wall
Pilasters at Pilasters
Specified
Dimension
See Step 4 for instructions on mounting the stirrup brackets to a pilaster.
Slide the wall-hung pilaster into the stirrup brackets
and align with the established level line . Refer to the
submittal drawing and adjust to meet the specified
dimension .
A
Using the bracket as a template, drill Ø1/4" holes
through the pilaster at each pilaster bracket hole .
Secure the pilaster to the bracket using the
#10-24 x 1/2" barrel nuts and #10-24 x 3/4" shoulder
screws provided .
B
Slide the wall-hung pilaster into the stirrup brackets
and align with the established level line . Refer to the
submittal drawing and adjust to meet the specified
dimension .
A
Using the bracket as a template, drill Ø1/4" holes
through the pilaster at each pilaster bracket hole .
Secure the pilaster to the bracket using the
#10-24 x 1/2" barrel nuts and #10-24 x 3/4" shoulder
screws provided .
B
CL
Notch
indicates
bottom of
pilaster .
Notch indicates
bottom of
pilaster .
6e Wall-Hung Pilasters (72") – Stirrup Brackets (Optional)
Refer to the
submittal drawing
for the correct
orientation
of the pilaster .
Refer to the
submittal drawing
for the correct
orientation
of the pilaster .
Floor
6" Ref .
(152)