Page 40
9e1034
Tekniske data
Forsyning
12-35Vdc (ripple max. 30%)
max. strøm
12A kont.
20A 30% on / 70% off
Tomgangsstrøm 10mA t ypisk
Aktuelt forbrug
område1,5A (start 1.5x)
område2,
5-10A (start 1.5x)
therm. besk.
120°C
start tid
0-3s justerbar
Stop tid
0-3s justerbar
operations freq. 2kHz
Spænd. tab.
0.6V ( Im 12A )
Kontrol input
"1" = 4-30Vdc , "0" = 0-1V
Fejl output
NPN open-coll. 30V 50mA
oper. temp.
-10...60°C
Vægt
105g
1 2 3 4
5 6 7 8 9 10
FEJL LAMPE
START TILSTAND
on
STYRINGSTILSTAND
STRØM
GRÆNSE
SOFT
START
SOFT
STOP
off
3 s
0
3 s
0
5 A
1 0 A
2 0 A
1 0 A
5 A
1 A
STRØM
GRÆNSE
STYRINGSLOGIK
+
-
PNP NPN
24V
dc
0V
0V
(g
nd)
M
123
4
+
-
FR
EM
TIL
BA
GE
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
On O
On O
On O
On O
On O
Strømgrænse 2-10A:
Styringstilstand:
On = Impulstryk; Off = Konstanttryk
Starttilstand:
On = Kun modsat retning
Off = Begge retninger
Soft-start (accelleration):
Justeres trinløst 0-3 sek.
Soft-stop (decelleration):
Justeres trinløst 0-3 sek.
Strømgrænse:
Finjustering.
Stryringslogik:
NPN (LINAK-betjeninger)
Stryringslogik:
PNP
Strømgrænse 2-5A:
Strømgrænse 10-20A:
område2,
10- 20A (start 1.5x)
7.2 CONTROL BOARD
12-35 V
Direct voltage
(Wobble max. 30 %)
12 A
Direct current
20 A
30 %
on
/
70 % off
Typi
cal
10 mA
Area
1,5 A (
Start
1,5x)
Area
from
2,5
to
10 A (
Start
1,5x)
Area from 2,1 to 20 A (Start 1,5x)
120 °C
0-3 s
Adjustable
0-3 s
Adjustable
2
kH z
0,6 V (Gr. 12 A)
1 = 4-30 VDC, 0 = 0-1 V
NPN koll.off. 30 V 50 mA
-10 bis 60 °C
105
g
Technical data
:
Power Supply
Max. current
No-load current
Current consumption
Therm. msg.
Start time
Stopp
time
Operating frequency Voltage
Control input
Error output
Operator. temp
Weight
Start mode
ON
=
Only opposite direction
OFF
=
Both directions
Control mode
:
On = Pulse pressure /Off = Constant pressure
Power limit
2-5 A:
Power limit
2-10 A
Power limit
10-20 A:
Softstart (Beschleunigung
:
Progressive Justierung 0-3 s
Softstopp (Verlangsamung):
Progressive Justierung 0-3 s
Strombegrenzung:
Softjustierung
Steuerungslogik:
NPN (LINAK-Steuerungen)
Steuerungslogik:
PNP
Fejl lampe = Fehlerkontrollleuchte
Frem = Vorwärts
Tilbage = Rückwärts
Start Mode
:
On = Only opposite direction
Off = Both directions
Control Mode
:
On = Pulse pressure /Off =
Constant pressure
Current limit
2-5 A:
Current limit
2-10 A
Current limit
10-20 A:
S
oft
start
(acceleration)
(
Steplessly
adjustable 0-3 sec)
Soft
stopp (
slackening of speed
):
Progressive
adjustable
0-3
Current limeting
:
Fine tuning
Control logic
:
NPN (LINAK-
Operations
)
Control
logi
c
:
PNP
Error lamp
F
or
w
ar
d (UP)
Back (DOWN)
Start mode
Control mode
Power limit
Power limit
Control logic