Page 16
9e1034
5.2 INSTALLATION OF GUIDE FOR LIFTING UNIT
Min.
Max
Remark
A
4.0 m
16.0 m
4.0
–
6.0
= 2 lifting unit
s
6.0
–
11.0 = 3 lifting unit
s
11.0
–
16.0
= 4 lifting unit
s
C1
0.7 m
1.1 m
Fixed measurement 0.7 m or 1.1 m (see section/table
7.2.2).
C2
0.7m
1.1 m
Measurement adapted to E, F, G (see section/table
7.2.2).
D
E, F, G
4.0 m
w
/
o
reinforcement*
4.8 m
w
/reinforcement*
The measurements must not differ from each other by
more than 0.4. E, F, G must be divisible by 0.4 (see
section/table 7.2.2).
H
0.65 m
0.75 m
H=0.65 m => height of floor adjusted
by
0.7 –
1.0 m
H=0.75 m => height of floor adjusted
by
0.8 –
1.1 m
*The reinforcement is welded to the longitudinal stringer between the lifting units (see
section
below).
Ramp
When installing the plastic gratings, always start from the end of the ramp and
work towards
the end
of the staircase. Measurements E, F, G must always be divisible by 0.4 m to prevent a lifting unit
from being installed below a stringer for the grating.