INSTALLATION
6 720 644 842b (2010/12)
22
7.3
INSTALLING A TERMINAL GUARD
A Terminal guard must be fitted if the flue is less than
two metres from the ground or if a person could come
into contact with the flue terminal outlet.
B
Fit the terminal guard centrally over the flue inlet or
outlet.
B
Mount the terminal guard to the wall utilising the
three mounting points attached to the guard.
B
Fold the gates in the order stated below or the gates
will not latch properly.
1. Fold the single pronged gate in and latch onto the
guard frame.
2. Fold the two pronged gate in and latch onto the guard
frame.
Fig. 39 Terminal guard - flue outlet
Fig. 40 Terminal guard - flue inlet
NOTE:
The terminal end must not be
swivelled inside the guard. The terminal end
must be mounted at right angles with
respect to the wall.
The terminal guard does not have to be
fitted over the flue inlet, but is
recommended to protect the flue from third
party damage.
6720646219-31.1Wo
1.
2.
6720646219-32.1Wo
1.
2.