PRE-INSTALLATION
6 720 644 842b (2010/12)
10
REDUCING THE TELESCOPIC FLUE LENGTH
The flue terminal MUST be fitted with the 'TOP' label
uppermost to allow the correct fit and use of the plume
management system.
B
Remove securing screws (3) to detach the terminal
assembly from the turret.
B
Slide terminal section (2) from the terminal assembly
and discard.
B
To use terminal (1) without cutting remove the
location lug (4) on the inner flue tube (5) and remove
any burrs.
Fig. 10 Reducing the telescopic terminal
To reduce the telescopic flue length further:
B
Mark the length required for the terminal as shown in
figure 11 (min. 130mm) and cut square, taking care
not to damage the tubes.
B
Remove any burrs and chamfer the outer edge of the
tubes to assist ease of connection and prevent seal
damage.
Fig. 11 Further reduction
REDUCING EXTENSION FLUE TUBE LENGTH
B
Mark the extension tube to the required distance,
measuring from the socket end and cut the tube
square, taking care not to damage the tubes.
B
Remove any burrs and chamfer the outer edge of the
tubes to ease the connection and prevent damage to
the seals.
Fig. 12 Cutting an extension tube
Ensure that the TOP label of both sections
are aligned before securing the two parts at
the required length.
The aluminium tape is not required when
reducing the terminal.
6720643895-31.1Wo
2
3
1
A 220mm short extension is available
4
5
6
1
130 mm
485 mm
MIN
4
5
6
1
130 mm
265 mm
MIN
From standard telescopic flue
From longer telescopic flue
6720644842-35.1Wo
2
6720644842-07.1Wo
1
Summary of Contents for WORCESTER Condensfit II GREENSTAR 60/100 HORIZONTAL FLUE
Page 26: ...6 720 644 842b 2010 12 26 NOTES ...