AutoDome Pipe Mount
Installing the Pipe Mount | en
17
Bosch Security Systems, Inc.
Installation Guide
F.01U.251.410 | 1.0 | 2011.08
–
The second method is to bypass the Power Supply Box and
route the video, control, and alarm wires directly to the
Interface Board. You connect only the power wires inside
the Power Supply Box.
Figure 2.4
VG4-A-PSU1 or VG4-A-PSU2 Power Supply Box Con-
nected to Pipe Interface Board
GND TXD
RXD
C+
C-
GND TXD
RXD
C+
C-
P101
P106
P105
P107
XF102
XF103
XF101
5 4 3 2 1
J
J
J103
J102
J101
(LED)
HTR DOME
24V NC 24V
(FUSE
)
(FUSE
)
(FUSE)
BNC
J102
P107
P101
P102
P103
P104
P106
J101
AGND
A7
A6
A5
A4
A3
AGND
OUT 3
OUT 2
OUT 1
P105
VG4-A-PSU1/VG4-A-PSU2
Pipe Interface Board
1 120 VAC/230 VAC Power In 7
P101 Connector
2 P101 Connector
8
P107 Connector
3 Ground Connection
9
24 VAC Power In (to AutoDome)
4 Transformer
10
Earth Ground
5 24 VAC Power Out
11
24 VAC Power In (to AutoDome)
6 P107 Connector
12
24 VAC Power In (to Heater)
13
24 VAC Power In (to Heater)
14
AutoDome Power
15
Heater Power
NOTICE!
Fiber Optic Models require that the Biphase control wires be
routed from the Power Supply Box P106 connector out to the
Pipe Interface Board P105 connector.