Configuring an Open Collector Output
Outputs 1, 2, and 3 are open collector types. These outputs
must be connected to a positive voltage between 5 and 32 V to
complete the circuit, with a maximum voltage rating of 32 VDC
@ 150 ma.
1.
Connect the appropriate stripped wire to the open
connector (1, 2, or 3) of the transistor.
2.
Connect the appropriate stripped wire to the ground
(GND) connector.