AutoDome Pipe Mount
Alarms and Relay Connections | en
47
Bosch Security Systems, Inc.
Installation Guide
F.01U.251.410 | 1.0 | 2011.08
3.
From the AutoDome main menu select Alarm Setup>Inputs
Setup, and set Alarm Input # to N.C.S. See the table below
for contact and condition details.
4.3
Configuring Non-supervised Alarms
(inputs 1 through 7)
You can configure alarms 3 through 7 as non-supervised
Normally Open (N.O.) or Normally Closed (N.C.) alarms.
4.3.1
Configuring a Normally Open Non-supervised
Alarm
1.
Connect the alarm to the appropriate input (1 through 7)
and ground at the AutoDome.
Figure 4.3
N.O. - Normally Open Non-supervised Connections
2.
From the AutoDome main menu select Alarm Setup>Inputs
Setup, and set Alarm Input # to N.O. See the table below
for contact and condition details.
AutoDome Programmed N.C.S.
Contact
Alarm Condition
Open
Alarm
Closed
Normal
Short
Tamper
1
Dry Contact
3
Dome Connector
2
Alarm Inputs 1 to 7
4
Ground
AutoDome Programmed N.O.
Circuit
Alarm Indication
Open
Normal
Closed
Alarm