26
en | Installing the Pipe Mount
AutoDome Pipe Mount
F.01U.251.410 | 1.0 | 2011.08
Installation Guide
Bosch Security Systems, Inc.
4.
Attach the control data in/out wires to their respective
terminals on the P105 connector on the Pipe Interface
Board. Refer to
Figure 2.6, Page 23
, for an illustration of
these connections.
5.
Connect the 24 VAC power wires to the P101 connector on
the Pipe Interface Board. If this model has a heater,
connect the 24 VAC heater power wires to connector
P107.
6.
To connect alarm inputs and outputs, attach the supplied
6-pin Alarms In and the 4-pin Alarms Out connector plugs
with flying leads to the appropriate alarm wires. Then
connect the plugs to their mating connectors P103 and
P102 on the Pipe Interface Board.
Figure 2.7
Alarm and Relay Connector Plugs
WARNING!
Do not connect the RJ45 connector unless using UTP video or
Ethernet. This connection causes video distortion.
CAUTION!
To protect the AutoDome from damage due to cold
temperatures, ensure that you connect the 24 VAC heater
power wires to the P101 connector.
1
1
2
3
4
5
6
2
3
4
N
.O. COM
N.
C
.
A1 GND
A2
PIN
PIN
P102
P103
P104
WHITE
ORANGE
BROWN
GREEN
WHITE
ORANGE
BROWN
GREEN
YELLOW
BLUE