![Bosch Solution 64 Installer'S Manual Download Page 61](http://html.mh-extra.com/html/bosch/solution-64/solution-64_installers-manual_39390061.webp)
Solution 64 | Installer Guide | Output Programming
Bosch Security Systems | 11/05 | BLCC110I
8-9
Output Event Type Table
0 = Disabled
1 = Battery Trouble
P
26 = Entry Time
A
51 = Senior Watch
A
2 = AC Trouble
P
27 = Exit Time
A
52 = Exit Error
A
3 = Telephone Line Trouble
P
28 = End Of Exit Time
A
53 = RF Key Fob Function 1
A
4 = Comm Fail – Destination 1 / 2 P
29 = Chime On
A
54 = RF Key Fob Function 2
A
5 = Third Dialler Attempt
P
30 = Chime Zone Triggered
A
55 = Output Pre- Alert
A
6 = Destination 1 Reporting
P
31 = Auto Arm Pre-Alert
A
56 = Follow PIN Code
U
7 = Destination 2 Reporting
P
32 = Ready To Arm All On
A
57 = Part Entry Time
A
8 = Destination 1 or 2 Kiss Off
P
33 = Ready To Arm Part On
A
58 = Time Schedule
S
9 = Destination 1 Kiss Off
P
34 = Ready To Arm Part 2 On
A
59 = Temperature Alarm
K
10 = Destination 2 Kiss Off
P
35 = Closing Report Sent OK
A
60 = Access Group
G
11 = Dialler Disabled
P
36 = External Siren (Spk Beeps)
A
12 = Output Device Missing
P
37 = Internal Siren (Spk Beeps)
A
13 = Output Trouble
O
38 = Alarm Any (silent or Audible ) A
14 = Panel On Line
P
39 = Fire Alarm
A
15 = Incoming Call
P
40 = Burglary Alarm
A
16 = System Trouble
P
41 = Silent Alarm
A
(A) = Area Event Assignment
17 = Box Tamper
P
42 = Duress Alarm
A
(P) = Panel Event Assignment
18 = Zone Trouble
Z
43 = Keypad Medical
A
(O) = Output Event Assignment
19 = Zone Mirror
Z
44 = Keypad Fire
A
(Z) = Zone Event Assignment
20 = Zone Alarm
Z
45 = Keypad Panic
A
(U) = User Event Assignment
21 = Area Disarmed
A
46 = Device Tamper
A
(S) = Schedule Event Assignment
22 = Area Armed (Any)
A
47 = Access Denied
A
(G) = Access Group Event Assignment
23 = Area All On
A
48 = Strobe
A
(K) = Keypad
24 = Area Part On
A
49 = Smoke Sensor GND
A
25 = Area Part 2 On
A
50 = Sensor Watch
A
Table19: Output Event Types
Output Default Table
The table below lists the default values for all Output parameters in the Solution 64. Outputs 1 to 3 are High current digital
outputs and Output 4 is the onboard relay output. Outputs 5 to 8 are available when the optional Output Relay Expander Board
(CM110) is fitted. Options marked N/A = Not Applicable.
Programming Option
Output 1 Output 2 Output 3 Output 4 Output 5 Output 6 Output 7 Output 8
Output Name
External
Siren
Strobe
Light
Smoke
Sensor PWR
Internal
Siren
Output 5
Name
Output 6
Name
Output 7
Name
Output 8
Name
Event Type
36
(External
Siren)
48
(Strobe)
49
(Smoke
Sensor GND)
37
(Internal
Siren)
0
0
0
0
Event Assignment
1
1
1
1
1
1
1
1
Output Polarity
14
6
11
6
0
0
0
0
Time Parameter
N° Of Hours
000
008
000
000
000
000
000
000
N° Of Minutes
005
000
000
005
000
000
000
000
N° Of Seconds
000
000
010
000
000
000
000
000
N° Of 1/10 Seconds
000
000
000
000
000
000
000
000
Output Options
Do not Operate If Low Battery
Y
Y
Y
Y
N
N
N
N
Display Output Overload
Y
Y
Y
N/A
N/A
N/A
N/A
N/A
Report Output Overload
Y
Y
Y
N/A
N/A
N/A
N/A
N/A
Display Missing Output Device
Y
N
N
N/A
N/A
N/A
N/A
N/A
Report Missing Output Device
Y
N
N
N/A
N/A
N/A
N/A
N/A
Reserved
N
N
N
N
N/A
N/A
N/A
N/A
Reserved
N
N
N
N
N/A
N/A
N/A
N/A
Reserved
N
N
N
N
N/A
N/A
N/A
N/A
Table 20: Output Default Table