Solution 64 | Installer Guide | Programming Overview
Bosch Security Systems | 11/05 | BLCC110I
4-3
Service Mode
Service mode when activated disables dialler reporting,
prevents all alarms and prevents all users from arming the
system.
Turning Service Mode ON
Enter Program Mode.
[1234 + MENU]
Turn Service Mode On.
[MENU 7-0-8]
Follow Display Prompts.
Hold down MENU to exit.
i
Note
Keypads will display the word “SERVICE” in the middle of the
display when service mode is active.
Turning Service Mode OFF
Enter Program Mode.
[1234 + MENU]
Turn Service Mode On.
[MENU 7-0-8]
Follow Display Prompts.
Hold down MENU To Exit.
i
Note
You must exit Service Mode to reactivate the system. Service
mode will automatically exit after 2 hours.
Defaulting the System
Defaulting the system will reset all programming options back
to the factory default setting. All programming information will
be erased.
Hardware Default
Remove All Power To The System. AC and Battery.
Press and Hold The Default Push Button Down Then Apply
Power To The System.
Release Button, The Panel Will Reset And Revert To Normal
Operation When Default Is Complete.
Software Default
Enter Program Mode.
[1234 +MENU]
Select Factory Default Option.
[MENU 7-0-4)
The Panel Will Reset And Revert To Normal Operation When
Default Is Complete.
i
Note
You can disable factory defaulting using MENU 7-7-4. If factory
defaulting has been disabled you must know the installer PIN to
perform a factory default otherwise the system will need to be
returned to your supplier for defaulting. Charges will apply.
1)
2)
3)
4)
1)
2)
3)
4)
1)
2)
3)
1)
2)
3)
Triggering a Duress Alarm
If your PIN is 2580, to send a duress report when the area is off,
Enter, [2] + [5] + [8] + [0] + [8] + [0] + [OK] or [ON].
If your PIN is 2580, to send a duress report when the area is on,
Enter, [2] + [5] + [8] + [0] + [8] + [0] + [OFF].
i
Note
Duress alarms are triggered by entering the user PIN followed by
the last 2 digits of the user PIN followed by the ON or OFF key.
Domestic Template Defaults
The following table list the changes that will occur when you
select domestic default. See MENU 7-0-3 — Domestic Default.
Program Option
Domestic Default Value
Default Value
Default Value
Value
All Trouble Reports
Disabled
All Bypass Reports
Disabled
All Restore Reports
Disabled
Destination 1 TX Format
Domestic Reporting
Open / Close Reports
Disabled (all areas)
System Events Route
Log Only
Table 12: Domesting Reporting Defaults
Direct Link Programming
The panel can be programmed via the SolutionLink™ Upload/
Download software in either Direct Link or Remote Link modes.
For Direct Link you will need a CM900 Direct Link module
which is used to connect the panels serial port to the PC.
Once the cable is connected you will need to hold down
the default switch on the panel for 5 seconds to initiate the
programming session. See the board layout drawings in
Section 3 of this manual for the default switch location.