9-8
Software
IPC 40.2
DOK-SUPPL*-IPC*40.2***-PR02-EN-P
This tab indicates the current measured values of the internal operating
voltages, the battery voltage, the system temperature and the status of
the fan function.
upsc5-health.BMP
Fig. 9-6:
"System Health" tab
The value of the battery voltage (
Battery Voltage
) is only updated after a
battery test. The battery test occurs automatically after a system start and
then every 12 hours or after pressing the button
Test Battery
.
•
The LED flashes red, if the value of the battery voltage measured on
load is too low.
•
The LED flashes green, if the battery pack is ready for operation.
Note:
Excessive battery tests will discharge the battery pack. Never
perform more than five battery tests within a period of 24
hours.
The following applies to the fan monitoring (
Fan Speed
):
•
Red LED: Fan stands still, or fan speed is too low or too high.
•
Green LED: Fan is working properly.
Pressing the button
StopAutoRefresh
disables the automatic updating of
the measured values and the labeling on the button changes to
AutoRefresh
.
Pressing the button
AutoRefresh
disables the automatic updating of the
measured values and the labeling on the button changes to
StopAutoRefresh
.
System Health