IPC 40.2
Maintenance and Installation
8-1
DOK-SUPPL*-IPC*40.2***-PR02-EN-P
8
Maintenance and Installation
8.1 General
Information
The IPC 40.2 are maintenance-free. Some components are subject to
wear and must be replaced.
Include the following measures in your maintenance schedule:
•
At least once a year, check all plug and terminal connections for
proper tightness and damage. Check that cables are not broken or
crushed. Replace damaged parts immediately.
•
Check the fan at least once a year.
DANGER
Risk of injury through rotating fan impeller!
⇒
Keep hands and fingers clear of the fan impeller, and
do not insert any items.
•
Ensure that the batteries of the IPC 40.2 are fully functional. Activate
the battery test of the UPS program, so that the battery pack is
checked during each restart.
Note:
Concerning spare parts function compatibility is ensured for at
least 5 years.
8.2 CMOS
Battery
The battery, with which RAM and clock are buffered, has a limited service
life (see chapter "Wear parts" starting on page 4-4).
This lithium battery may not be changed by the user. The battery may only
be exchanged by the Bosch Rexroth Service (see chapter "Service &
Support" starting with page 13-1) or by personnel specially trained and
authorized by the Service.
Maintenance