background image

7-6

 Connections

IPC 40.2

DOK-SUPPL*-IPC*40.2***-PR02-EN-P

Ethernet Interface XEthernet

The IPC 40.2 can be connected with an Ethernet network via the
XEthernet interface.

RJ45 female connector, 8-pin

Type:

Ethernet 10Base T / 100Base X

Cable length:

Max. 100 m

Cable type:

Shielded, twisted pair

Transmission rate:

10 or 100 Mbits/s

max. 100 m

1

8

2

1

3

4

5

6

7

8

XEthernet RJ45

To the network

XEthernet

ethernet_sst.cdr

Fig. 7-6:

Ethernet interface XEthernet

The driver configuration of the network connection can be called up in the
task bar or in the "Control Panel" with icon "Network Board". Here you can
set among other values, if the data transfer shall occur with 10 Mbits/s
and/or with 100 Mbits/s.

Note:

Please observe that the network board of the outstation has to
be able to process the same data transmission rate.

VGA Interface XVGA

An external monitor (CRT) can be connected to the VGA connection
(XVGA) and can be operated parallel to the integrated flat screen via the
integrated video adapter.

  Video RAM: Max. 8 MB

Note:

Please observe that the external monitor has to be already
connected during the booting process of the IPC 40.2, as
otherwise the VGA interface is not initialized by the BIOS.

Note:

Before plugging-in a graphic card the video adapter integrated
in BIOS has to be switched off.

XEthernet – Network connection

XVGA – Connection for an

External Monitor

Summary of Contents for Rexroth IPC 40.2

Page 1: ...ontrol VCP 20 Industrial Hydraulics Electric Drives and Controls Linear Motion and Assembly Technologies Pneumatics Service Automation Mobile Hydraulics Rexroth IPC 40 2 R911307652 Edition 02 Project Planning Manual ...

Page 2: ...served in the event of the grant of a patent or the registration of a utility model or design DIN 34 1 The specified data is for product description purposes only and may not be deemed to be guaranteed unless expressly confirmed in the contract All rights are reserved with respect to the content of this documentation and the availability of the product Bosch Rexroth AG Bgm Dr Nebel Str 2 D 97816 L...

Page 3: ...eneral Information 3 3 3 5 Protection Against Contact with Electrical Parts 3 4 3 6 Protection Against Electric Shock by Protective Low Voltage PELV 3 5 3 7 Protection Against Dangerous Movements 3 6 3 8 Protection Against Magnetic and Electromagnetic Fields During Operation and Mounting 3 7 3 9 Protection Against Contact with Hot Parts 3 8 3 10 Protection During Handling and Mounting 3 8 3 11 Bat...

Page 4: ...T1 7 4 USB Interfaces 7 5 Ethernet Interface XEthernet 7 6 VGA Interface XVGA 7 6 Combined Keyboard Mouse Interface 7 8 Mouse Interface 7 8 PC Power Supply 7 9 Battery Connection 7 13 Optional Interfaces 7 14 8 Maintenance and Installation 8 1 8 1 General Information 8 1 8 2 CMOS Battery 8 1 8 3 Hard Disk 8 2 8 4 Rechargeable Battery Pack 8 4 8 5 Extension Cards 8 6 Installing an Extension Card 8 ...

Page 5: ... and Cables 10 2 Connecting Cables to the VDP 16 1 VDP 40 1 and VDP 60 1 GIGASTAR Interface 10 2 Fastening Brackets 10 2 11 List of Figures 11 1 12 Index 12 1 13 Service Support 13 1 13 1 Helpdesk 13 1 13 2 Service Hotline 13 1 13 3 Internet 13 1 13 4 Vor der Kontaktaufnahme Before contacting us 13 1 13 5 Kundenbetreuungsstellen Sales Service Facilities 13 2 ...

Page 6: ...IV Contents IPC 40 2 DOK SUPPL IPC 40 2 PR02 EN P ...

Page 7: ... 2 can also be equipped with a GIGABIT interface to connect the Rexroth operator panels BF 312T and BF 315T or a GIGABIT3 interface to connect the displays BTT 16 1 or BTT 40 1 The IPC 40 2 consists of two tightly connected parts The PC box contains the PC including the hard disk and the power supply unit with uninterruptible power supply Depending on the variant the PC box provides three or four ...

Page 8: ... PC box Type A Type C Free slots 3 4 Power supply 85 264 VAC or 24 VDC Integrated UPS Integrated UPS_Logic battery pack to be externally connected Optional drives CD ROM DVD CD RW Fig 1 2 PC box type A and type C 1 3 Operating System For license reasons the IPC 40 2 devices are only delivered with already installed operating system 1 4 Commissioning Mount the device properly for this see chapter D...

Page 9: ...e guarantee and the right to payment of damages resulting from inappropriate use are forfeited The user alone carries all responsibility of the risks Before using Bosch Rexroth products make sure that all the pre requisites for appropriate use of the products are satisfied Personnel that in any way shape or form uses our products must first read and understand the relevant safety instructions and ...

Page 10: ... are Handling and assembly systems Packaging and foodstuff machines Printing and paper processing machines Machine tools Wood working machines The IPC 40 2 may only be operated under the assembly installation and ambient conditions as described here temperature system of protection humidity EMC requirements etc and in the position specified 2 2 Inappropriate Use Using the IPC 40 2 outside of the a...

Page 11: ...son or persons responsible for the safe operation of this equipment If the equipment is resold rented or transferred or passed on to others then these safety instructions must be delivered with the equipment WARNING Improper use of this equipment failure to follow the safety instructions in this document or tampering with the product including disabling of safety devices may result in material dam...

Page 12: ...RNING High electrical voltage due to wrong connections Danger to life or bodily harm by electric shock WARNING Health hazard for persons with heart pacemakers metal implants and hearing aids in proximity to electrical equipment CAUTION Surface of machine housing could be extremely hot Danger of injury Danger of burns CAUTION Risk of injury due to improper handling Bodily harm caused by crushing sh...

Page 13: ...he country of use The equipment is designed for installation in industrial machinery The ambient conditions given in the product documentation must be observed Use only safety features and applications that are clearly and explicitly approved in the Project Planning Manual If this is not the case they are excluded The following areas of use and application for example include safety features and a...

Page 14: ...re switching on power the ground wire must be permanently connected to all electrical units according to the connection diagram Do not operate electrical equipment at any time even for brief measurements or tests if the ground wire is not permanently connected to the points of the components provided for this purpose Before working with electrical parts with voltage higher than 50 V the equipment ...

Page 15: ...onductor connection Prior to startups even for brief tests always connect the protective conductor or connect with ground wire Otherwise high voltages can occur on the housing that lead to electric shock 3 6 Protection Against Electric Shock by Protective Low Voltage PELV All connections and terminals with voltages between 0 and 50 Volts on Rexroth products are protective low voltages designed in ...

Page 16: ...ger to life risk of injury severe bodily harm or material damage Ensure personal safety by means of qualified and tested higher level monitoring devices or measures integrated in the installation Unintended machine motion is possible if monitoring devices are disabled bypassed or not activated Pay attention to unintended machine motion or other malfunction in any mode of operation Keep free and cl...

Page 17: ...ompatibility EMC test on the installation 3 8 Protection Against Magnetic and Electromagnetic Fields During Operation and Mounting Magnetic and electromagnetic fields generated near current carrying conductors and permanent magnets in motors represent a serious health hazard to persons with heart pacemakers metal implants and hearing aids WARNING Health hazard for persons with heart pacemakers met...

Page 18: ...g Under certain conditions incorrect handling and mounting of parts and components may cause injuries CAUTION Risk of injury by incorrect handling Bodily harm caused by crushing shearing cutting and mechanical shock Observe general installation and safety instructions with regard to handling and mounting Use appropriate mounting and transport equipment Take precautions to avoid pinching and crushi...

Page 19: ...responding to the information in the respective Project Planning Manual must be provided with pressurized media such as compressed air hydraulic oil cooling fluid and cooling lubricant supplied by external systems Incorrect handling of the supply and connections of pressurized systems can lead to injuries or accidents In these cases improper handling of external supply systems supply lines or conn...

Page 20: ...3 10 Safety Instructions for Electric Drives and Controls IPC 40 2 DOK SUPPL IPC 40 2 PR02 EN P Notes ...

Page 21: ...in D SUB 1 x parallel interface 25 pin D Sub 1 x external VGA connection 15 pin HD Sub 2 x USB connection type A 1 x Ethernet connection RJ 45 10 100 Base T 1 x keyboard connection PS 2 1 x mouse connection PS 2 1 x external battery connection 1 x RS422 interface 9 pin D Sub Additional interfaces For variant without special interfaces 3 x serial standard interface RS232 9 pin D Sub 1 Slots 2 x PCI...

Page 22: ...nt from all output voltages as the maximum total output power 160 W must not be exceeded Fig 4 2 Technical data of the power supply unit 115 V 230 V 4 3 Technical Data of the Power Supply Unit 24 V Nominal input voltage 24 VDC Input voltage range 24 VDC 20 15 Noise and surge immunity Umax 35 V for t 100 ms Max input current 6 A for nominal voltage 24 V Max inrush current 25 A for nominal voltage 2...

Page 23: ...he function Fig 4 4 Ambient conditions 4 5 Used Standards The system components of the IPC 40 2 correspond to the following standards Standard Meaning EN 60 204 1 Electrical equipment of machines EN 50 081 2 Basic technical standard emitted interference industrial environment EN 50 082 2 Basic technical standard noise immunity industrial environment EN 60 742 Transformer for 24 V power supply unit...

Page 24: ...ng in additional extension cards the UL compliancy has to be verified 4 6 Wear Parts CMOS battery 5 to 7 years Battery pack The number of charging cycles of the battery pack and thus its service life is dependent on the ambient temperature in which the battery pack is used Ambient temperature surrounding air temperature is defined as the temperature in which the industrial PC or the battery pack i...

Page 25: ...the ambient conditions specified for the overall device in chapter 4 4 have to be absolutely kept Also fans are mechanic wear components whose service life is extremely temperature dependent For the fan integrated in the housing the manufacturer specifies the following service life Ambient temperature surrounding air temperature Service life 40 C 70 000 hours 70 C 35 000 hours Fig 4 8 Service life...

Page 26: ...4 6 Technical Data IPC 40 2 DOK SUPPL IPC 40 2 PR02 EN P ...

Page 27: ...0 2 IPC_40_2_Masse_3Slot FH9 Fig 5 1 Horizontal mounting of the IPC 40 2 device with 3 slot box The IPC 40 2 may be mounted horizontally net connection on the left side as well as vertically net connection on the top The height of the IPC 40 2 depends on the slot number of the used PC box PC box Number of slots Height of the IPC 40 2 Type A 3 130 2 mm plus 10 mm for the screw of the hard disk cove...

Page 28: ...accessories brackets are provided see page 10 3 with which the IPC 40 2 can also be mounted upstanding on a wall 214 68 4 105 350 6 5 262 5 7 364 Upstanding with additional bracket Angle IPC_40_2_Rückansicht_3Slot FH9 Fig 5 3 Mounting of the IPC 40 2 upstanding on a wall ...

Page 29: ...erface to connect the Rexroth operator panels BF 312T and BF 315T or a GIGABIT3 interface to connect the displays BTT 16 1 or BTT 40 1 These displays operator panels are equipped either with a keypad or with a touch screen with varying display seize Note Detailed information you will find in the corresponding documentation You can also connect a standard monitor female connector XVGA a PS2 keyboar...

Page 30: ...ck supply voltage at the power supply unit LED green Normal mode Vo LED OFF Internal 5 V supply faulty LED OFF Normal mode T LED yellow flashing Over temperature Reduce ambient temperature surrounding air temperature Check fan at the PC LED OFF Normal mode LED red Industrial PC is currently operating in battery mode i e no power supply available Restore power supply and initiate controlled BTV res...

Page 31: ...ig 7 1 Position of the interfaces 7 2 Interfaces Note Not each variant provides all the described interfaces Which interfaces are integrated in the respective device depends on the device configuration Note Malfunctions caused by insufficient shielding Use only shielded cables and metallic conductive connector or coupling covers with large area screen contact ...

Page 32: ...2 male connector 6 pin o X10 PC power supply 24 VDC as an alternative to X20 Male connector terminal MSTB 1 5 4 pin Female connector terminal MSTB 1 5 4 pin o X19 Battery for uninterruptible power supply Tyco AMP MATE N LOK 2 pin Cable to the battery of the UPS o X20 PC power supply 230 115 VAC Inlet male connector for non heating apparatus Inlet female connector for non heating apparatus o X39 or...

Page 33: ...7 3 Pin assignment XCOM1 to XCOM3 Note Depending on the variant and the used software packages the interfaces can be already taken Settings of the Serial Interfaces To find out settings of the transfer parameters for the serial interfaces please refer to the description of the installed operating system for Windows 95 NT select Settings Control Panel The standard BIOS setting of the COM1 Serial Po...

Page 34: ... 17 18 GND SEL out ERROR INIT SEL in 19 GND 20 21 GND 22 23 24 25 GND GND GND GND GND Write Data0 Intr Wait n u Datastb GND n u n u n u Addrstrb GND GND GND GND GND GND GND Data1 Data3 Data7 Data2 Data4 Data5 Data6 Data1 Data3 Data7 Data2 Data4 Data5 Data6 To peripheral devices parallel_sst cdr Fig 7 4 XLPT1 interface The parallel interface normally runs in the standard mode SPP Furthermore it can...

Page 35: ...eed 500 mA If the load exceeds 500 mA the internal current monitoring is activated Note The USB interfaces are not supported by the operating system Windows USB_P XUSB2 XUSB1 Shield USB_M USB device Shield applied to the metal housing of the plug in connection XUSB 2 3 4 1 XUSB 1 2 3 4 usb_sst cdr Fig 7 5 USB interfaces XUSB1 and XUSB2 Pin Function 1 USB power supply max 500 mA 2 Data 3 Data 4 USB...

Page 36: ...d Here you can set among other values if the data transfer shall occur with 10 Mbits s and or with 100 Mbits s Note Please observe that the network board of the outstation has to be able to process the same data transmission rate VGA Interface XVGA An external monitor CRT can be connected to the VGA connection XVGA and can be operated parallel to the integrated flat screen via the integrated video...

Page 37: ...can be operated with an image refresh rate of min 72 Hz VGA mode 640 x 480 pixels 32 bits colors SVGA mode 800 x 600 pixels 32 bits colors XGA mode 1024 x 768 pixels 32 bits colors SXGA mode 1280 x 1024 pixels 24 bits colors The resolution and number of the colors is set in the Control Panel of the operating system CAUTION Setting incorrect resolutions and colors may destroy your monitor Please ob...

Page 38: ...ouse Interface PS 2 Mini DIN female connector 6 pin Cable length Max 1 5 m Cable type Shielded cross section min 0 14 mm Interrupt IRQ 12 BIOS presettings PS 2 mouse support Enabled PS 2 mouse Auto detect Mouse Clock Mouse Data max 1 5 m Mouse Power 5 VDC Shield applied to the metal housing of the plug in connector XMouse 1 2 3 4 5 6 GND Shield maus_sst cdr Fig 7 9 Mouse interface XMouse If a PS 2...

Page 39: ...ants for 24 VDC All internally required voltages are generated with electrical isolation via a DC DC converter The connection is designed as connector terminal MSTB 1 5 4 pin To this connector terminal cables with a cross section of maximum 1 5 mm can be connected X10 4 24V 24V 0V 0V 4 1 2 3 2 3 1 Pin Assignment _ x10 cdr Fig 7 10 Pin assignment of the 24 VDC connection X10 Parameters Value Rated ...

Page 40: ...C voltage components such as resulting from an uncontrolled 3 phase current bridge connection without smoothing with a ripple factor see DIN 40110 10 75 section 1 2 of 5 are permissible It follows from the above that as upper voltage limit the greatest absolute value is 30 2 V and as lower voltage limit the lowest absolute value is 18 5 V t 1 05 x 28 8 V 30 2 V Upper limit 28 8 V 0 866 x 30 2 V 26...

Page 41: ...ps with a maximum length of 20 cm The cross section of the copper strips has to be at least equal to that of the incoming mains cable 3 0 75 mm up to 6 m 1 5 mm up to 10 m Distances exceeding 10 m require a separate local power supply unit Terminals in isolated arrangement 102 green yellow 2 A Terminal block 42 B Terminal block 102 Length max 4 m 62 1 blue 0 V 24 V Earth bar Cross sections dependi...

Page 42: ...0 115 VAC connection occurs via a 3 pin inlet connector for non heating apparatus on the connector panel The maximum cable cross section for the connected cables is 1 5 mm 2 X20 Assignment PE N1 U2 PE 230V_Buchse cdr Fig 7 15 Pin assignment of the 230 115 VAC connection X20 Parameters Value Rated voltage 85 VAC 264 VAC auto range Power consumption for UN 230 VAC 0 7 A Power consumption for UN 115 ...

Page 43: ...uses motor protection key preferred L1 1 L2 1 L3 1 N 230 V supply operator terminals service plug receptacles U2 E g drives Incoming mains PE star point Overvoltage category III Overvoltage category II L1 L2 L3 N green yellow green yellow green yellow green yellow green yellow green yellow trenntrafo cdr Fig 7 17 Voltage connection 230 VAC via isolating transformer Battery Connection Connection te...

Page 44: ... The first is connected to the 15 pin RJ45 female connector X29 and the second to the 15 pin D Sub female connector X31 GIGABIT3 Interface The GIGABIT3 interface is assigned to the 25 pin D Sub female connector X71 To this female connector you connect via a ready made cable available as accessory see page 10 3 a display BTT 16 1 or BTT 40 1 GIGASTAR Interface The GIGASTAR interface is assigned to ...

Page 45: ...ng fan impeller Keep hands and fingers clear of the fan impeller and do not insert any items Ensure that the batteries of the IPC 40 2 are fully functional Activate the battery test of the UPS program so that the battery pack is checked during each restart Note Concerning spare parts function compatibility is ensured for at least 5 years 8 2 CMOS Battery The battery with which RAM and clock are bu...

Page 46: ...rges Comply with all ESD protection measures during working with modules and components Avoid electrostatic discharges Note To store user data and to avoid the re installation of the operating system and application programs after a hard disk exchange you should back up the well working hard disk at regular intervals Note The hard disk to be inserted must already have an installed operating system...

Page 47: ... disk is connected to the main board Now the installation frame with hard disk can be removed Display rear view Hard disk frame Retaining screw Festplattentausch FH9 Fig 8 1 Position of the hard disk s installation frame and the retaining screw 5 The new hard disk is delivered including the installation frame The new hard disk is always mounted with the installation frame in reverse order as descr...

Page 48: ... off As long as the IPC 40 2 is connected to the supply system a total discharge of the battery pack is avoided The number of charging cycles of the battery pack and thus its service life is dependent on the ambient temperature in which the battery pack is used Ambient temperature surrounding air temperature is defined as the temperature in which the IPC 40 2 and the battery pack is situated e g t...

Page 49: ... 4 Position and pin assignment of the battery connection DANGER Ensure that the polarity of the batteries is correct In the case of a polarity reversal of the batteries a F10A 5x20 fuse is released on the power supply unit Note If the new battery pack is not yet charged during the charging time there s no sufficient USP protection enabling a controlled shutdown of the PC Therefore use completely c...

Page 50: ...on cards by electrostatic discharges Comply with all ESD protection measures during working with modules and components Avoid electrostatic discharges CAUTION Risk of damage to the IPC 40 2 or corruption of application software by integrating not released extension cards Install only released extension cards and have them installed by skilled employees Installing an Extension Card 1 Disconnect the...

Page 51: ...housing cover and the mounting screw 5 The cover closing the air gap must be removed 6 Remove the fastening screws from the slot cover 7 Place the extension card and fix it with the fastening screw Extension board for 3 cards ISA PCI slot A1 PCI slot A2 Slot cover PCI slot A3 Cover Erweiterung FH9 Fig 8 6 Position of the slots for extension cards ...

Page 52: ...ts IRQ etc with other extension cards or connected devices occur In the event that after a system reboot the functions based on the new card are not available there may be several reasons The card is not properly seated in the PCI or ISA slot The driver software of the card has not been installed or its installation is faulty IRQ Interrupt conflict with other PC hardware components The software of...

Page 53: ...CI IRQ line 3 PCI IRQ line 4 Option Disabled Auto IRQ 3 4 5 7 9 10 11 12 14 15 Default AUTO In the BIOS menu The Advanced Menu PCI Configuration sub menu PCI PNP ISA IRQ Resource Exclusion IRQx the IRQ address for not Plug and Play compliant ISA cards Legacy ISA cards is set BIOS selection IRQ 3 4 5 7 9 10 11 15 Option Available Reserved Default Available In the BIOS menu The Advanced Menu PCI Con...

Page 54: ...8 10 Maintenance and Installation IPC 40 2 DOK SUPPL IPC 40 2 PR02 EN P ...

Page 55: ...t temperatures remain within the non critical range In the case of application sensitive procedures ensure that machine movements are terminated in a controlled manner before the temperature monitoring function switches off the IPC 40 2 Uninterruptible Power Supply UPS In the event of a voltage breakdown or if the temperature exceeds 65 C the UPS logic of the IPC 40 2 s power supply unit allows a ...

Page 56: ...ed Select PROFIBUS Address set the COM interface for the touch screen controller set the SIS interface mode The communication between program and UPS occurs via the serial interface The program consists of two parts a Control Panel Applet and the Windows NT service The task of the UPS program is in case of a voltage breakdown within a determinable time delay time maximum 60 seconds to send a messa...

Page 57: ...ective operating status of the service is indicated in the Windows task bar betr_zust tif Key 1 Service has been started but is not ready for operation yet 2 Service is in operation 3 Service is in operation however errors have been indicated during the start battery temperature fan and voltage errors Fig 9 2 Indication of the operating status of the service in the Windows task bar In the service ...

Page 58: ...he user can not terminate the program without administration rights or stop the monitoring ups_nt_control_icon tif Fig 9 4 Symbol UPS NT Control in the Windows Control Panel After selecting symbol UPS NT Control the window USV Properties and Maintenance appears The window offers the following tabs in which further settings can be made UPS General tab System Health tab Profi Bus Touch Mode tab SIS ...

Page 59: ...dialog under COM port If no interface is found during the starting process of the service a corresponding dialog is opened and the service is terminated In the range Advanced Controls the following settings are possible Shutdown Delay Time Here a delay time for the shutdown from 0 45 s is determined This is the time the user has to back up his data After the expiration of the delay time all applic...

Page 60: ...s still active after a temperature warning Enable Fan Control If this check box is activated the existing housing and CPU fans are monitored In error case a corresponding message is indicated and send to the whole system Enable Voltage Control If the check box is activated the internal supply voltages are monitored In error case a corresponding message is indicated and send to the whole system No ...

Page 61: ...red and activated If several programs have to be executed or if the programs have transfer parameters they have to be combined and entered in a batchfile Note The entry must not contain any request parameters and the specified program must not start any shutdown If you activate the Default button all settings are reset to their standard values These are COM Port COM4 Shutdown Delay Time 30 sec Ena...

Page 62: ...of the battery voltage measured on load is too low The LED flashes green if the battery pack is ready for operation Note Excessive battery tests will discharge the battery pack Never perform more than five battery tests within a period of 24 hours The following applies to the fan monitoring Fan Speed Red LED Fan stands still or fan speed is too low or too high Green LED Fan is working properly Pre...

Page 63: ...Select COM3 Connection XCOM3 COM3 is accessible at connection XCOM3 Keyboard Controller COM3 is internally connected with the Keyboard Controller to request the status of the M Keys via the serial interface see section M Keys in chapter 6 or reload firmware into the Keyboard Controller Fig 9 8 Select COM3 connection Note The following applies to all settings The UPS service is stopped All changes ...

Page 64: ...ount indicated in the About tab indicates how often the UPS has already shut down the system A battery change is recommended after more than 3000 trips by the UPS but not later than the recommended maintenance interval see section 4 6 upsc5 about BMP Fig 9 9 About tab About ...

Page 65: ...en the XCOM2 interface is not situated on the connector panel The required driver software is already installed ex works Changes are possible in the application Pointer Devices in the Windows Control Panel You can reach the same setup program via Start programs UPDD Settings UPDD_start bmp Fig 9 10 UPDD setup programs for the touch screen A dialog window appears for the different settings UPDD_set...

Page 66: ...f required you can calibrate the touch mouse with the help of this program For this touch one after the other the middle of the four crosses displayed on the screen For further information on this programs refer to the online help which you can start directly as file GENER EN CHM in folder D Programs UPDD ...

Page 67: ...thout special interface N 8 System configuration 8 1 Pentium III min 933 MHz min 10 GB P8 9 Connecting voltage 9 1 AC 115 to 230 V 50 to 60 Hz C 9 2 DC 24 V D 10 Uninterruptible power supply UPS 10 1 without integrated accu N 11 Disc drive 11 1 CD ROM D 11 2 DVD CD RW distiller E 12 Other design 12 1 none NN 13 Firmware and software 13 1 Denotes that firmware and software must be ordered as separa...

Page 68: ... 170156 Connection cable for external battery pack BTV 16 40 60 cable length 1 0 m Fig 10 3 Battery Pack and cables Connecting Cables to the VDP 16 1 VDP 40 1 and VDP 60 1 GIGASTAR Interface Ordering designation Part number Description BKS U H G4 IPCVDP 001 0 P R911307684 Connecting cable IPC VDP high flexible 1 m BKS U H G4 IPCVDP 005 0 P R911306043 Connecting cable IPC VDP high flexible 5 m BKS ...

Page 69: ...rface 7 4 Fig 7 5 USB interfaces XUSB1 and XUSB2 7 5 Fig 7 6 Ethernet interface XEthernet 7 6 Fig 7 7 XVGA interface 7 7 Fig 7 8 Combined keyboard mouse interface XKeyb 7 8 Fig 7 9 Mouse interface XMouse 7 8 Fig 7 10 Pin assignment of the 24 VDC connection X10 7 9 Fig 7 11 Technical data of the 24 VDC connection 7 9 Fig 7 12 Safety transformer according to EN 60742 7 10 Fig 7 13 Illustration of th...

Page 70: ...eneral tab 9 5 Fig 9 6 System Health tab 9 8 Fig 9 7 Profi Bus Mode COM3 tab 9 9 Fig 9 8 Select COM3 connection 9 9 Fig 9 9 About tab 9 10 Fig 9 10 UPDD setup programs for the touch screen 9 11 Fig 9 11 Dialog window to set the touch screen 9 11 Fig 10 1 Type code IPC 40 2 10 1 Fig 10 2 Connectors and cables 10 2 Fig 10 3 Battery Pack and cables 10 2 Fig 10 4 Connecting cables to the VDP 16 1 VDP ...

Page 71: ...ay time 9 5 Dimensions 5 1 Display and Operating components 6 1 E Ethernet connection 7 6 Ethernet interface 7 6 External monitor 7 7 H Housing dimensions 5 1 I Illustration of the limit values for the 24 VDC voltage 7 10 Inappropriate use 2 2 Consequences Discharge of liability 2 1 Interfaces 7 1 7 2 PS 2 keyboard 7 8 PS 2 mouse 7 8 VGA interface 7 6 XCOM1 7 3 XCOM2 7 3 XCOM3 7 3 XEthernet 7 6 XL...

Page 72: ...Serial interfaces XCOM1 to XCOM3 7 3 surrounding air temperature 4 3 System presentation Brief description 1 1 Commissioning 1 2 Operating system 1 2 Variants 1 2 System Presentation 1 1 T Technical data Wear parts 4 4 Technical data Ambient conditions 4 3 PC box 4 1 Power supply 24 V 4 2 Used standards 4 3 Technical Data Power supply unit 115 V 230 V 4 2 Technical Data 4 1 Technical data 230 115 ...

Page 73: ... connection 7 7 VGA interface 7 6 Video adapter CRT 7 7 Voltage connection 230 VAC via isolating transformer 7 13 W Wiring of the power connection 24 VDC and the IPC 40 2 terminal 7 11 X XCOM1 7 3 XCOM2 7 3 XCOM3 7 3 XLPT1 interface 7 4 XVGA interface 7 7 ...

Page 74: ...12 4 Index IPC 40 2 DOK SUPPL IPC 40 2 PR02 EN P ...

Page 75: ...Sie bitte zuerst Kontakt mit unserem für Sie nächstgelegenen Ansprechpartner auf Die Angaben in der vorliegenden Dokumentation können seit Drucklegung überholt sein At www boschrexroth com you may find additional notes about service repairs and training in the Internet as well as the actual addresses of our sales and service facilities figuring on the following pages sales agencies offices providi...

Page 76: ... from 7 am 6 pm Tel 49 0 9352 40 42 22 Vertriebsgebiet Süd Germany South Bosch Rexroth AG Landshuter Allee 8 10 80637 München Tel 49 0 89 127 14 0 Fax 49 0 89 127 14 490 Vertriebsgebiet West Germany West Bosch Rexroth AG Regionalzentrum West Borsigstrasse 15 40880 Ratingen Tel 49 0 2102 409 0 Fax 49 0 2102 409 406 49 0 2102 409 430 Gebiet Südwest Germany South West Bosch Rexroth AG Service Regiona...

Page 77: ...24 88 30 Italy Italien Bosch Rexroth S p A Via Mascia 1 80053 Castellamare di Stabia NA Tel 39 081 8 71 57 00 Fax 39 081 8 71 68 85 Italy Italien Bosch Rexroth S p A Via del Progresso 16 Zona Ind 35020 Padova Tel 39 049 8 70 13 70 Fax 39 049 8 70 13 77 Italy Italien Bosch Rexroth S p A Via Isonzo 61 40033 Casalecchio di Reno Bo Tel 39 051 29 86 430 Fax 39 051 29 86 490 Netherlands Niederlande Holl...

Page 78: ...a no 250 sector 3 73429 Bucuresti Tel Fax 40 0 21 255 35 07 40 0 21 255 77 13 Fax 40 0 21 725 61 21 eastel rdsnet ro Romania Rumänien Bosch Rexroth Sp zo o Str Drobety nr 4 10 app 14 70258 Bucuresti Sector 2 Tel 40 0 1 210 48 25 40 0 1 210 29 50 Fax 40 0 1 210 29 52 Russia Russland Bosch Rexroth OOO Wjatskaja ul 27 15 127015 Moskau Tel 7 095 785 74 78 7 095 785 74 79 Fax 7 095 785 74 77 laura kani...

Page 79: ...al Compound Narol Naka Makwana Road Andheri East Mumbai 400 059 Tel 91 22 28 56 32 90 91 22 28 56 33 18 Fax 91 22 28 56 32 93 singh op boschrexroth co in India Indien Bosch Rexroth India Ltd S 10 Green Park Extension New Delhi 110016 Tel 91 11 26 56 65 25 91 11 26 56 65 27 Fax 91 11 26 56 68 87 koul rp boschrexroth co in Indonesia Indonesien PT Bosch Rexroth Building 202 Cilandak Commercial Estate...

Page 80: ...5 335 5511 michael moro boschrexroth ca Canada West Kanada West Bosch Rexroth Canada Corporation 5345 Goring St Burnaby British Columbia Canada V7J 1R1 Tel 1 604 205 5777 Fax 1 604 205 6944 Hotline 1 604 205 5777 david gunby boschrexroth ca Mexico Bosch Rexroth Mexico S A de C V Calle Neptuno 72 Unidad Ind Vallejo 07700 Mexico D F Tel 52 55 57 54 17 11 Fax 52 55 57 54 50 73 mariofelipe hernandez b...

Page 81: ......

Page 82: ... Controls P O Box 13 57 97803 Lohr Germany Bgm Dr Nebel Str 2 97816 Lohr Germany Phone 49 0 93 52 40 50 60 Fax 49 0 93 52 40 49 41 service svc boschrexroth de www boschrexroth com Printed in Germany DOK SUPPL IPC 40 2 PR02 EN P R911307652 ...

Reviews: