①
Connector for supply voltage of connector set S01
②
Connector for supply voltage of connector set S04
Fig.7-2:
Connector for supply voltages
Observe the color-coding of the connectors.
To connect the operating voltages, only the feeder connector that
is contained in the connector set available as accessories for the
IndraControl L45/L65/L85 is allowed, see
Accessories (Connector Set)" on page 69
. The R-IB IL SCN-PWR
IN-CP connector, which is available for other power terminals, is not
allowed for the IndraControl L45/L65/L85!
Connector contact
Signal
1.1
DC +24 V segment voltage (U
S
)
1.2
DC +24 V supply voltage (U
LS
)
1.3
LGND (ground, supply voltage)
1.4 and 2.4
FE (functional earth ground)
2.1
DC +24 V uninterruptible power supply (UPS), currently not
supported
DOK-CONTRL-ICL45L65L85-PR01-EN-P
Rexroth IndraControl L45/L65/L85 Control
Bosch Rexroth AG
33/81
Connections and Interfaces