102/176 CANopen
Bosch Rexroth AG
, MIT: ID 40, 3 842 530 344/2014-05
9.9.1.1 Object 1600-1601: Receive PDO mapping parameters
These parameters are available in the 160x objects, whereby x + 1 stands for the
number of each RPDO channel.
Table 35: RPDO mapping 1
Index
Subindex
Description
Value (index)
1600
00
No. mapped objects
8
01
PDO valid
2040/01
02
Commanded link state
2600/02
03
Auto mode configuration
2600/03
04
SLK operative flag
2600/04
05
MDT counter - high byte (byte 3)
2600/05
06
MDT counter - byte 2
2600/06
07
MDT counter - byte 1
2600/07
08
MDT counter - low byte (byte 0)
2600/08
Table 36: RPDO mapping 2
Index
Subindex
Description
Value (index)
1601
00
No. mapped objects
8
01
PDO valid
2041/01
02
MDT status
2800/01
03
Byte at MDT address 0x0000
2200/01
04
Byte at MDT address 0x0001
2200/02
05
Byte at MDT address 0x0002
2200/03
06
Byte at MDT address 0x0003
2200/04
07
Byte at MDT address 0x0004
2200/05
08
Byte at MDT address 0x0005
2200/06
9.9.1.2 Object 1A00-1A03: Transmit PDO mapping parameters
These parameters are available in the 1A0x objects.
Table 37: TPDO mapping 1
Index
Subindex
Description
Value (index)
1A00
00
No. mapped objects
8
01
PDO valid
2030/01
02
Actual link state
2600/01
03
Auto mode configuration
2600/03
04
SLK operative flag
2600/04
05
MDT counter - high byte (byte 3)
2600/05
06
MDT counter - byte 2
2600/06
07
MDT counter - byte 1
2600/07
08
MDT counter - low byte (byte 0)
2600/08