142/176 Web interface
Bosch Rexroth AG
, MIT: ID 40, 3 842 530 344/2014-05
10.5.5 MDT data page
This page allows full write and read access to the entire MDT user data area.
To
read the MDT data
, enter MDT address ranges in the
Address Ranges
input field.
Chapter 10.5.12 “Syntax when entering values” describes how to make the entries.
Enter the number of bytes per line in
Bytes per Line
. When the
Offset
is displayed in
hexadecimal format, 8, 16 or 32 is recommended; when displayed in decimal format,
10 is recommended.
The
Read Data
button reads the data from the MDT and displays it in the bottom
window of the MDT data section.
Note that either the MDT has to be located in front of the SLK in the
CONNECTED
state or the data areas matching the request are from the previous MDT. If this is not
the case, the web interface designates the bytes that cannot be read from the MDT
with two red question marks, see Chapter 10.5.1.5 “Error on MDT data page”.
Transmitting the MDT data can take some time, depending on the amount of data
requested.
If you want to
write MDT data
, enter the start address of the MDT data area in the
input field next to
Offset
. Edit the data itself in the field next to
Write Data
. The
format described in Chapter 10.5.1.2 “Syntax when entering values” also applies
here. You can enter up to 92 bytes separated by commas or spaces.