Introduction 17/176
3 842 530 344/2014-05, MIT: ID 40,
Bosch Rexroth AG
Operating state switches due to an
event
Table 3: Relationship between events and link states
Event during communication
Event only possible in link
state (display)
Results in link state (display)
MDT signs on to SLK
CONNECTING (WAI)
PRECONNECTED (PRE)
PRECONNECTED
ends and auto
reconnect is active (see
Chapter 5.3.3 “Auto mode")
PRECONNECTED (PRE)
CONNECTING (WAI)
PRECONNECTED
ends and auto
disconnect is active (see
Chapter 5.3.3 “Auto mode")
PRECONNECTED (PRE)
DISCONNECTED (OFF)
PRECONNECTED
ends and auto
mode is not active (see
Chapter 5.3.3 “Auto mode")
PRECONNECTED (PRE)
CONNECTED (CON)
Error during MDT sign-on
CONNECTING (WAI)
ERROR (E00)
Error during direct data
exchange with MDT
CONNECTED (CON)
Note
:
The error is output through
the bus in the form of an error
message and does not alter
the state
CONNECTED (CON)
Error during MDT sign-off
PRECONNECTED (PRE)
CONNECTED (CON)
Note
:
Can occur during commanded
link states DISCONNECT,
RECONNECT, ERROR or when
PRECONNECTED ends and
auto mode is active (see
Chapter 5.3.3 “Auto mode")
ERROR (E00)
MDT leaves early
CONNECTED (CON)
Note
:
Can occur when a workpiece
pallet is released too early in
the application.
ERROR (E00)
Appendix 16.1 “ID 40 system link model” describes the states and state transitions
in detail.
PROOF COPy 1 | 20.05.2014 | FOR INTERNAL USE ONLy
EN
GLISH