Operating condition
Value
Ambient temperature with Rexroth servo motor
0 °C ... 40 °C, above 40 °C loss of performance
Ambient temperature for mechanical system (without dropping
below dew point)
–10 °C ... 60 °C
Travel distance s
min
1)
See “Technical data” tables in the catalog
Soiling
Not permissible
1)
Minimum travel to ensure a reliable lubrication distribution.
EN
GLISH
R320103174/2018-08 | Function modules
Bosch Rexroth AG
29/30
15 Disposal
The product contains a number of different materials: Aluminum, steel, plastics, grease and possibly electronic
components.
NOTICE
Environmentally hazardous materials can pollute the environment if not disposed of properly!
Environmental pollution.
f
Collect any escaping lubricant and dispose of it correctly.
f
The product and its components must be disposed of correctly and in compliance with all applicable national
and international guidelines and regulations.
16 Technical data
Technical data
!
“Function modules” catalog.
17 Operating conditions
Tabelle 10: Operating conditions
17.1
Tightening torques
18 Notes
We use screws of strength class 8.8 as standard. If other screws are used, this is indicated.
8.8
M2
M2.5
M3
M4
M5
M6
M8
M10
M12
M14
M16
u
M
A max
(Nm)
0.4
0.7
1.3
2.7
5.5
9.5
23
46
80
127
194
m
= 0.125
Tabelle 11: Tightening torques