A
C
B
A
Fig. 12:
FMS drive types
16/30
Bosch Rexroth AG
Function modules | R320103174/2018-08
7 Mounting the FMS drive
NOTICE
Risk of excessive torque and rotary speed if limit values are not adhered to!
Avoid tension due to the weight of the motor when mounting the motor!
Damage to the product.
f
Observe the specified limit values. Technical data and limit values
!
catalog.
7.1
Mounting the motor with mount and coupling
The screw journal of the function module and the motor journal must be completely free of grease and oil
before mounting.
Observe the tightening torques
!
1.
Push the coupling (4) onto the screw journal (5) of the function module (1) and tighten the screw (6) (system-
side) to tightening torque M
A
.
2.
Push the mount (3) into the centering (2) on the function module (1) and tighten to the end plate (8) using four
screws (7) and tightening torque M
A
.
3.
Push the motor (9) into the centering of the mount and coupling and using four screws (10) tighten to
tightening torque M
A
.
4.
If necessary, release the motor brake and move the carriage (12) so that the screw journal can turn, and tighten
the motor-side clamping screw (11) of the coupling to tightening torque M
A
(through the bore in the mount).
Drive types:
• Mount and coupling (B) with motor (A)
• Timing belt side drive (C) with motor (A)