![Bosch Rexroth FMB Instructions Manual Download Page 22](http://html.mh-extra.com/html/bosch/rexroth-fmb/rexroth-fmb_instructions-manual_39565022.webp)
L
- +
R
Bosch Rexroth AG
D-97419 Schweinfurt
Made in Germany
7210
CNR:
R12345678
TYP:
FMB-110-DN-1
CS:
9876543210 0030 0001
FD:
5129
s
max
(mm) u (mm/U) v
max
(m/s) a
max
(m/s
2
) M1
max
(Nm)
d
i
--
--
--
--
--
--
--
MNR:
R11617000
4
1
2 3
5
7
8
9
10
11
12
13
14
15
6
1
CNR
Customer's part number
2
TYP
Short product name
3
110
Size
4
CS
Customer information
5
MNR
Part number
6
FD
Manufacturing date
7
7210
Manufacturing location
8
s
max
Maximum travel range
9
u
Lead constant without motor attachment
10
v
max
Maximum speed
11
a
max
Maximum acceleration
12
M1
max
Maximum drive torque at motor journal
CW
CCW
X
22/30
Bosch Rexroth AG
Function modules | R320103174/2018-08
13
d
Direction of motor rotation to move in positive (+)
direction
CW = clockwise
CCW = counterclockwise
14
i
Gear ratio
15
QR code (for start-up)
10.1
Easy start-up using the integrated wizard
EasyWizard is the standard assistant integrated in the Rexroth engineering framework IndraWorks DS to help you
commission drives of Linear Motion Systems easily and quickly. Starting up has never been easier thanks to
pre-configured data sets and a nameplate on the Linear Motion Systems that is keyed to the wizard.
• Quick, easy and intuitive start-up
• Text-based and graphical online help for the individual input fields
• Plausibility checks when it comes to free data entry
• Compatible with all Rexroth Linear Motion Systems
• Incorrect parameter settings are minimized by the similar arrangement of the data on the nameplate and the
wizard input mask
• For system optimization, the axis can be traversed in the test mode after parameterization
Fig. 19:
Nameplate
10.2
Checking the operating conditions
X
Observe ambient temperature, load, speed and stroke
!
“Checking the operating conditions” on page 22
section and catalog.
X
For special operating conditions, please contact us.