Installation
29
ME 200 – 6720884576 (2019/08)
3.3.4
Overview of the terminal assignment
This overview indicates which system parts can be connected for all
terminals in the module. Depending on the system, one of the
components can be connected to the terminal (e.g. “VR2” or “PR2”
to the terminal “VR2”). Depending on what the module is used for,
simultaneous connection of a number of components may be required,
or may need to be excluded.
Legend for fig. above and figs. 21 for 29 at the end this document
(terminal designation
grau
Components with a grey background can be connected
as an option
*
Components of the system are possible alternatives
230 V AC Mains voltage connection
AHS
Alternative heat source with signal input; extra-low voltage
1)
or mains voltage side; On/Off or 0-10 V signal for modulation
(Alternative Heat Source) (
A
lternative
H
eat
S
ource)
AHSP
Alternative heat source without signal input
(
A
lternative
H
eat
S
ource
P
assive)
B
Buffer cylinder (
B
uffer)
BC
Wall-mounted indoor unit electronics (
B
asic
C
ontroller)
CC
Combi cylinder (
C
ombi
C
ylinder)
CHC
Conventional heat source: condensing storage combi heating
centre (
C
ombi
H
eating
C
entre)
CON
Control unit with EMS 2 BUS system; signal input/output for
systems with conventional and alternative heat sources and
coding switch setting one (
Con
troller)
CONM
Control unit with EMS 2 BUS system; signal input/output for
systems with stand-alone alternative heat sources and coding
switch setting 10 (
Con
troller
M
aster)
DHWC
DHW cylinder (
D
omestic
H
ot
W
ater
C
ylinder)
HS
Conventional heat source (
H
eat
S
ource)
Only establish HS to OEV connection with control units with
EMS 1 device electronics; the connection is not required with
EMS 2 device electronics
FS
Freshwater station (
F
reshwater
S
tation)
MC
Heat source electronics (
M
aster
C
ontroller)
PR1
120/230 V AC: pump of alternative heat source
(
P
ump
R
eturn); ≤ 24 V: control signal
2)
with stand-alone
alternative heat sources (0-10 V/PWM) for output control
PR2
Connection of pump for heating circuit 1 with stand-alone
alternative heat sources
MS
Solar module (
S
olar
M
odule)
T1
Outside temperature sensor, only required with coding
switch setting 10 (
T
emperature sensor),
TA1
Alternative heat source flow temperature sensor
(
T
emperature
A
lternative)
TB1
Buffer cylinder temperature sensor at top
(
T
emperature
B
uffer)
TB2
Buffer cylinder temperature sensor at centre
TB3
Buffer cylinder bottom temperature sensor
TB4
System flow temperature sensor
TF1
Alternative heat source flue gas temperature sensor
(
T
emperature
F
lue gas)
TR1
Alternative heat source return temperature sensor
(
T
emperature
R
eturn)
TR2
Heating system return temperature sensor
VB1
Mixer connection
3)
Buffer cylinder return (
V
alve
B
uffer)
VR1
Alternative heat source return
(
V
alve
R
eturn)
VR2
Connection of diverter valve to bypass conventional heat
source
CON
BC/MC
CON
BC/MC
HS
AHS/
AWE
CONM
(autark)
TR2
T1
TF1
TA1
TB4
TB3
TB2
TB1
TR1
PR1
PWM
1 2 3
0-10V
M
VR2*
PR2*
N L
M
PR1
N L
M
VR1
N
M
N
4
43 44
M
VB1
N
4
43 44
230 V AC
230 V AC
N 14
PR1
120/230 V AC
N L
N
44 15
N 43
L
16
N
120/230VAC 120/230VAC
VB1
OA3
1 2 1
OEV
1 2 1 2
T1
TR2
OA1
ME 200
120/230 V AC
24 V
0
1
2
3
4 5 6
7
8
9
10
10
2 3
1 2
BUS
1
4
2
1 2
BUS
43 44
VR1
N
N 14
VR2
on/off
OA2
0-10 V
BUS
Adr.9-10
1 2 1
TB2 TB3
1 2 1 2
TR1 TB1
24 V
2 1
2 3
TB4 TA1
TF1
OR1
4
2
1
3
1 2
PWM: 1-2
0-10 V: 1-3
0010016173-003
AHS/
AWE
1) Terminal assignment on extra-low voltage side: 1, 2 – On/Off (max. 24 V); 3 –
earth; 4 – 0-10 V signal
2) Terminal assignment: 1 - earth; 2 - pulse width modulation/0-10 V output; 3 -
pulse width modulation input
3) Note with diverter valve: terminal 43 acts in direction of buffer cylinder