![background image](http://html.mh-extra.com/html/bosch/ds7060/ds7060_reference-manual_38837012.webp)
Page 12
Copyright
2001 Detection Systems, Inc.
DS7060-AUS Reference Guide
•
Easy Exit:
If the system is armed and there have been
no zones violated, then you can reenter a Quick Arm
Command without first disarming the system. This
allows you to change the arming level or to restart the
exit delay so you can exit through an entry/exit zone.
•
Force Arming Limit:
If enabled, the system can be
armed when zones are violated or if an AC power failure
has occurred, by pressing the [Bypass Key] after an
arming command. If bypassing is not allowed, a three
beep error tone will sound and the panel will return to
standby mode.
Note:
If “Auto Bypass” (Address 10) is enabled,
arming the panel will automatically bypass the
corresponding number of zones programmed into Force
Arming Limit. If “Auto Bypass” is disabled, any zones
that were programmed to be bypasses in Address 02,
may be Auto Bypassed.
•
Auto Bypass:
If enabled, the system will automatically
bypass faulted zones when an arming command is
used. If bypassing is not allowed on the “Not Ready”
zone, a three beep error tone will sound, and the panel
will return to standby mode.
Note:
When enabling Auto Bypass, it may be
desirable to program “Force Arming Limit” (Address
10). If “Force Arming Limit” is set to 0, Auto Bypass will
allow bypassing of any zone that was programmed to
be bypassed by Address 02. If “Force Arming limit” is
programmed between 1 and 6, this is the maximum
number of zones that can be Auto Bypassed.
6.11 Address 11 - Keypad Assignment
The keypad type (LED or Alpha) or no keypad must be
programmed.
6.12 Address 12 thru 18 - Alpha Label
•
Address 12
: Private Label - The private label will
display when the system is Ready to Arm and when it is
Armed.
•
Address 13
: Zone 1 Alpha Label:
•
Address 14
: Zone 2 Alpha Label:
•
Address 15
: Zone 3 Alpha Label:
•
Address 16
: Zone 4 Alpha Label:
•
Address 17
: Zone 5 Alpha Label:
•
Address 18
: Zone 6 Alpha Label:
Armed
Status
Power
Fire
Ready To Arm
ABC Alarm
Private Label
Move cursor left
Move cursor right
Accept Value
Don't accept (Hold for
2 seconds to exit)
UPPER/lower
case toggle
O Q Z
7 P R S
8 T U V
9 W X
4 G H I
5 J K L
6 M N O
SPACE
1 , '
& / # !
2 A B C
3 D E F
0
1
2
3
4
5
6
7
8
9
*
#
Example: To program “ABC Alarm” as the Private Label
Enter the Programmer’s Mode:
[9] [8] [6] [#] [0]
Enter the Program Address:
[1] [2] followed by [#]
Enter:
[2] for the letter “A” then press the right
arrow key for the next letter.
Enter:
[2] twice for the letter “B” then press the right
arrow key for the next letter.
Enter:
[2] three times for the letter “C” then press
the right arrow key for the next letter.
Enter:
[1] until you have a blank space. Note:
moving the cursor to the left does not create
a space. Spaces must be programmed into
the Alpha using the [1] key.
Enter:
[2] for the letter “A” then press the right
arrow key for the next letter.
[System Reset] This key is the upper/lower
case toggle.
Enter:
[5] three times for the letter “l” then press the
right arrow key for the next letter.
Enter:
[2] for the letter “A” then press the right
arrow key for the next letter
Enter:
[7] twice for the letter “r” then press the right
arrow key for the next letter.
Enter:
[6] for the letter “m”.
Enter:
[#] Program the next address, program a
different address, or exit the Programmer’s
Mode.