DS7060-AUS Reference Guide
Copyright
2001 Detection Systems, Inc.
Page 5
5.0 Operating Guide
5.1 Understanding the DS7443, DS7445, and DS7447 Keypads
•
The DS7443 is a 6 zone LED keypad; its LEDs represent the zones of the system.
•
The DS7445 is an 8 zone LED keypad; its LEDs represent the zones of the system (LEDs for zones 7 and 8 are not used).
•
The DS7447 is an alpha-numeric LCD keypad.
All three keypads display information on various control panel functions. A built-in sounder is used to annunciate keystroke
entries and as an interior warning device.
Volume Control
(DS7445 and DS7447 only): The keypad sounder volume can be adjusted using the [1] and [4] keys along
with the [*] key. Hold the [*] key while pressing the [1] key to increase the volume or the [4] key to decrease the volume. The
volume adjustment does not affect the volume during an alarm.
Backlight Control
(DS7447 only): The display backlight intensity can be adjusted using the [3] and [6] keys along with the
[*] key. Hold the [*] while pressing the [3] key to increase brightness or the [6] key to decrease brightness.
NOTE:
After the backlight and volume are adjusted, you must arm then disarm the system once to store this information in
the control panel. If power is disconnected before the panel is armed, the backlight and volume levels return to the
default settings.
Armed
Status
Power
Fire
On
Off
1
2
3
4
5
6
7
8
9
0
*
#
Bypass
Perimeter
No
Entry
Only
System
Reset
3
2
1
6
5
4
9
8
7
#
0
*
On
No
Entry
System
Reset
Bypass
Perimeter
Only
Off
Fire
Armed
Status
Power
1
2
3
4
5
6
Armed
Status
Power
Fire
On
Perimeter
Supervisory
Bell Silenced
Trouble
1 2 3 4 5 6 7 8
1
2
3
4
5
6
7
8
9
0
*
#
No
Entry
Reset
Off
Bypass
System
Only
Perimeter
DS7447 KEYPAD
DS7443 KEYPAD
DS7445 KEYPAD
This chart will help you understand what each Light/LED represents.
LIGHT
OFF
FLASHING
ON
Armed
(red)
The control panel is disarmed.
An exit delay is in progress or an
alarm has occurred.
The control panel is armed and no
alarms have occurred.
Status
(green)
One or more zones are not ready
to arm.
One or more zones are bypassed.
All zones are ready to arm.
Power
(green)
The control panel has lost power.
No AC for battery.
Control panel problems. Refer to
Error displays.
Normal operation.
Fire
(red)
There are no fire alarms.
A fire zone is in alarm.
A fire trouble condition exists.
Perimeter*
(yellow)
The perimeter is not armed.
This light will not flash.
The perimeter is armed.
Supervisory*
(yellow)
This light will not be sued by the
DS7060.
Not used.
Not used.
Bell Silenced*
(yellow)
The bells do not need to be or have
not been silenced.
This light will not flash.
The bells have been silenced. To clear,
enter the Fire Reset command.
Trouble*
(yellow)
There are no trouble conditions.
This light will not flash.
A trouble condition exists.
Zone LEDs**
(red)
There are no zone alarms.
A zone (1-6) is in alarm.
A zone (1-6) is not ready to arm or if a
fire zone, a trouble condition exists.
* = This light is present on the DS7445 only.
** = This light is present on the DS7443 and DS7445.