2.
Connect the optional ACU-PABX connection cable LBB 6721/03 to the
PABX connection of the DCU and the wires via a terminal strip to the PABX.
For wiring of the ACU-PABX connection cable see Table 6.3.
6.3.3 Software configuration of the ACU
Note
After installing and wiring the ACU card the software configuration has
to take place. This has to be done by use of the software installed on
the Alphadesk central control PC, described in the instructions for use of
the LBB 6511/00.
CHAPTER 6
Installation Instructions
18
DECT6000
9922
141
80271
03-07
en
Pin
Signal
Wire colour
Line
Pin
Signal
Wire colour
Line
14
a
white/blue
0
20
a
white/grey
4
1
b
blue/white
7
b
grey/white
2
earth
red/grey
8
earth
black/blue
15
a
white/orange
1
21
a
red/blue
5
3
b
orange/white
9
b
blue/red
16
earth
black/orange
22
earth
red/brown
17
a
white/green
2
23
a
red/orange
6
4
b
green/white
10
b
orange/reg
5
earth
grey/red
11
earth
blue/black
18
a
white/brown
3
24
a
red/green
7
6
b
brown/white
12
b
green/red
19
earth
orange/black
25
earth
brown/red
13
Not connected
Table 6.3 Connections of the ACU-PABX connection cable (LBB 6721/03)