2.
Connect the optional BS-DCU connection cable LBB 6721/02 to the BS 0-7 or BS
8-15 connector of the DCU (see figure 7.7). The wires of the connection cable must
be connected via a terminal strip, located near by a PABX, to the base stations (see
figure 7.3). For wiring of the BS-DCU connection cable (see Table 7.2).
RS232 connector for connection with Alphadesk central control PC
Mains inlet, 110...230 Vac/50..60 Hz, 1.6A
Fuse, T3.15 Ah/250 Vac
On/Off switch
7.3.3 Software configuration of the base station
Caution
When a new system has been set up or when base stations are
added to an existing system it is necessary to carry out a cable delay
measurement. This has to be done by use of the software installed on
the Alphadesk central control PC, described in the “Instructions For Use”
of the LBB 6511/00.
CHAPTER 7
Installation Instructions
DECT6000
23
9922
141
80271
03-07
en
1
2
4
3
Link card
not used
not used
A
CU 7
A
CU 6
A
CU 5
A
CU 4
A
CU 3
A
CU 2
A
CU 1
A
CU 0
BS 0-7
BS 8-15
Figure 7.7 Botttom view of the DCU
Pin
Signal
Wire colour
BS
Pin
Signal
Wire colour
BS
1
a
white/blue
0/8
5
a
white/grey
4/12
14
b
blue/white
18
b
grey/white
2
a
white/orange
1/9
6
a
red/blue
5/13
15
b
orange/white
19
b
blue/red
3
a
white/green
2/10
7
a
red/orange
6/14
16
b
green/white
20
b
orange/red
4
a
white/brown
3/11
8
a
red/green
7/15
17
b
brown/white
21
b
green/red
9...13
Not connected
22...25
Not connected
Table 7.2 Connections of the BS-DCU connection cable LBB 6721/02