3.3 Location and number of base stations
Before base stations are mounted within the facility it is necessary to determine their
quantity and location. To calculate this you must take into account that the coverage
area of base stations depends on construction and layout of the facility. The average
coverage area within buildings has a radius of 30-75 metres depending on building
material. Use the DECT6000 deployment kit LBB 6738/00 to determine the base
station locations.
Note
In case the entire area cannot be covered, (e.g. A remote area which
cannot be linked to the system with a cable) you can use repeaters to
extend the coverage area. For information about repeaters see chapter 9.
3.4 Location of the DCU
The location of the DCU depends on the location of the PABX and base stations in
order to minimise cable length. The Alphadesk central control PC has to be placed close
to the DCU, because the maximum cable length between Alphadesk central control PC
and the DCU is normally 3 metres. For a longer distance refer to chapter 5.2.2.
CHAPTER 3
Installation Instructions
4
DECT6000
9922
141
80271
03-07
en
BS
BS
BS
Figure 3.1 Example of top view with positions of base stations