Display Configuration | 11
Bosch Motorsport
DDU 10
83 / 188
Page switch
The pages can be switched from page one too twelve. If not all twelve pages are defined,
the device switches up to the highest defined page number, and ignores higher numbers,
which are not defined.
If the channel value does not only consist of integers, the pages will be switched as fol-
lows:
Page 1 is shown with the value < 1.5
Page 2 is shown with 1.5 <= the value < 2.5
Page 3 is shown with 2.5 <= the value < 3.5
…
Page 12 is shown with 11.5 <= the value
Brightness switch
The brightness can be switched with 6 positions. In the display settings dialog you will find
a chart for the 6 switch positions over the display brightness and the LED brightness (the
values are in percent).
If the channel value does not only consist of integers, the pages will be switched as fol-
lows:
Switch 1 is shown with the value < 1.5
Switch 2 is shown with 1.5 <= the value < 2.5
Switch 3 is shown with 2.5 <= the value < 3.5
…
Switch 6 is shown with 5.5 <= the value
11.6.2 Option 1: 12 Hardwired position switch
1.
Connect a 6 or 12 position switch to one of the analog input pins ANAxx and to the
sensor ground.
For recommended position switches, please see the environment section in the
chapter “Technical Data.”
2.
Select one of the analog inputs in the project tree.