6 | Analog and Frequency Inputs
26 / 188
DDU 10
Bosch Motorsport
6 Analog and Frequency Inputs
Analog inputs
– 0 to 5 V
– 12 bit A/D converter
– Switchable 3.01 kOhm pull-up resistor
– 10 kHz acquisition rate, up to 1 kHz recording rate
– Linear phase digital filter
Frequency inputs
– 5 V Hall-effect type, 2.5 V trigger level (DF11 input with current interface or 5 V Hall-
effect input with 2.5 V trigger level)
– 20 kHz max. frequency
– 10 ms measurement window
6.1 Analog inputs
6.1.1 Measurements channels
For each analog channel, several ‘subchannels’ are available.
Measurement labels with the characters ‘raw’ show the exact values in mV.
Measurement labels with the characters ‘_fi’ show filtered values.
The word ‘name’ in the table is a placeholder for the channel’s name.
Measurement label
Function
raw_name
mV value of sensor
raw_name_fi
Filtered mV value of sensor
name
Physical value of sensor
name_fi
Filtered physical value
Filtered channels are routed through digital low pass filters:
– DDU 10 uses A/D converter oversampling and digital filtering to recording rate
– Digital filters eliminate ‘out-of-band’ noise
– Cut-off frequency automatically adjusted to recording rate
– Linear phase – no signal distortion
– Latency compensation – no filter delay in recorded data