background image

D7212GV2 

 

 

 D7212GV2 Release Notes for Version 7.07  

 

F01U009079-04 

Page 2 

© 2007 Bosch Security Systems, Inc.  

2.0 

Corrections and Changes 

2.1 Version 

7.07 

The following corrections and changes were made in 
the D7212GV2 Control Panel since Firmware 7.06: 

 

The RPS port number prompt was renamed and 
moved from 

GV2AUX

 SDIRPS/ENHANCED 

CONF 

 BasePortNumber

 to 

GV2AUX 

 SDI 

RPS PARAMETERS 

 RPS Port Number

 in 

GV2AUX v1.03. 

 

The Anti-Replay enable prompt for the Anti-
Substitution feature was renamed and moved 
from 

GV2AUX 

 MISCELLANEOUS 

 

EnableAntireplay

 to 

GV2AUX 

 

ENHANCED COMM 

 Path #AntiReplay

 in 

GV2AUX v1.03. The value in the 

EnableAntireplay 

prompt when using GV2AUX 

v1.02 or older shows in the 

Path 1Anti-Replay

 

prompt. 

 

 

When you upgrade a D7212GV2 with 
firmware version 7.07 or later, you must 
enable the Anti-Replay option individually 
for each enhanced communication path if 
you are using this feature. Previously, one 
prompt applied to all destination paths. 

 

Changes were made to improve the reliability of 
the Time Sync feature. When enabled, this feature 
no longer causes intermittent erroneous skipping 
or duplication of skeds. This corrects the issues 
described in the 

G-GV2 Series Skeds Technical 

Bulletin

 from October 11, 2006 (P/N: TBI 10-5-06 

1 B G-GV2 Series Skeds). 

 

For optimal keypad user interface performance, 
ensure that any D1260 or D1260B Keypads 
connected to the system are running firmware 
version 1.04 or later. An update kit (P/N: R19-
D1260-0104) is available from Customer Service: 
(800) 289-0096. 

 

Changes made prevent the recent close alarm 
feature from interfering with panic alarm reports. 
Now, a panic alarm (an alarm generated by a 24-
hour point) is reported as a Burglar Alarm in any 
arming state. This corrects the issue described in 
the 

SIA CP-01 and Panic Alarms

 

Technical Bulletin

 

(P/N: F01U064901-01). 

 

Changes made prevent corrupted data account 
codes for systems that communicate with BIS 2.0 
Security Engine. These changes are only 
compatible with BIS Security Engine v2.1.1271 or 
later. This addresses the issues described in the 

BIS SEE and GV2/G Series Technical Service Note 

(P/N: F01U073249). 

 

Changes made allow the Relay Latches on point 
fault option for the 

P## Relay Response Type

 

feature to reset when a passcode is entered even 
when the associated point has not returned to 
normal. This correction does not apply to 
invisible points. 

 

Corrections made to the View Points menu in the 
D1260 and D1260B user interface now allow the 
display to advance even when there is only one 
viewable point in the area. This addresses the 
issue described in the 

Unresponsive D1260 Keypad 

Technical Bulletin

 (P/N: TBI 02-09-07 01). 

 

Corrections made now allow the use of any 
enhanced communication path in any route 
group. For example, Enhanced Communication 
Path 2 can be the primary destination for Route 
Group 4 with Phone Number 3 as backup. 
However, the primary and backup paths for any 
route group must be different. 

 

Changes made now allow the clearing of the 
alarm memory when there are only non-fire 
points faulted. However, the UL required 
prevention of alarm memory erasure while there 
are fire points faulted is still enforced. If an area 
has faulted fire and non-fire points, then the alarm 
memory is locked until the fire points are 
returned to normal. 

 

Changes made to the enhanced communication 
path acknowledgement wait time do not allow the 
no-ack-required option when anti-replay is 
enabled for the same path. When 

Path # Anti-

Replay

 is set to 

Yes

 and 

Path # ACK Wait 

Time

 with is set to 

0

, the zero value is treated as if 

it were the minimum setting of 5 seconds by the 
control panel. 

 

Changes made allow the Manual Idle Text 
Forward Scroll to show faulted points when you 
set 

CC# Scroll Lock

 to 

Yes

 and an alarm 

condition occurs. 

 

Changes made allow the View Area Status display 
on the D1260 and D1260B Keypads to show the 
default Area Arm Status text. 

Summary of Contents for D7212GV2

Page 1: ...07 RADXSKED v1 03 GV2AUX v1 01 Table 2 Supporting Literature for D7212GV2 with Version 7 07 Firmware and Later Document Name Part Number D7212GV2 Program Entry Guide F01U003804 03 D7212GV2 Program Record Sheet F01U003803 03 D7212GV2 Operation and Installation Guide F01U003805 02 D7212GV2 Approved Applications Compliance Guide F01U003806 02 Older revisions have alphabetic revision identifiers for e...

Page 2: ...nt corrupted data account codes for systems that communicate with BIS 2 0 Security Engine These changes are only compatible with BIS Security Engine v2 1 1271 or later This addresses the issues described in the BIS SEE and GV2 G Series Technical Service Note P N F01U073249 Changes made allow the Relay Latches on point fault option for the P Relay Response Type feature to reset when a passcode is e...

Page 3: ... is installed on the RPS workstation special software firewall settings might be required to allow outgoing traffic Refer to your firewall software for configuration information Any DX4020 or D9133TTL E used for enhanced communication to a central station receiver or with RPS over a network must be configured to use Datagram Mode 2 when the control panel firmware is version 7 06 and later Refer to...

Page 4: ...evice are now included when a test report is sent using COMMAND 41 or a sked Corrections enhance the reliability and performance of RPS network connection These corrections also decrease the delay in reporting a break in the Ethernet connection to the control panel s Network Interface Module within the time limits required by UL For UL 1610 Line Security formerly Grade AA Intrusion System installa...

Page 5: ... panel wide Communications Failure Relay output to activate when events in Route Groups 2 through 4 do not reach the central station Previously this relay output activated only on a communication failure for Route Group 1 2 5 Version 7 02 The Phone Line Supervision feature has improved accuracy in detecting the phone line The Modem IIIa2 product ID is changed to the same ID as the G Series control...

Page 6: ...ion This feature was updated to manage the control panel clock adjustments over a period of time instead of simply jumping to the new time This enhancement allows consistent execution of Skeds at their intended times When a TimeSync adjustment is in process the Time Date idle text display is modified with a or sign to indicate control panel time is increasing or decreasing to match the target time...

Page 7: ...ed Fire Bypass Trouble Annunciation The Fire Bypass warning display is modified to generate a Trouble warning tone that can be silenced with COMMAND 4 The trouble condition self clears when all bypassed fire points within the keypad s scope return to service This feature is always on and cannot be disabled Summary Fire Relay Options An option is added that changes the duration of the Panel Wide Su...

Page 8: ...s the Entry Delay starts If the system is not disarmed within the programmed time an Exit Error Alarm is generated This feature is always enabled and has no configuration parameters The alarm with an exit error event creates a new Modem IIIa2 message that the central station might need to add to their automation software Refer to Event 38 in the Modem IIIa2 Messages section of the Appendix in the ...

Page 9: ... after event transmission displays CANCEL RPT SENT on the keypad The burglary alarm cancel window duration is the time programmed in the A Alarm Bell prompt Duress Passcode Prompts Duress Type A Duress Enable L Send Duress A new duress option is available that allows any passcode with the L Send Duress permission set to Yes to always send a Duress Alarm event upon entry This feature allows the con...

Page 10: ...nd simplifies system operation Passcode Controlled Menus The system prompts a user to enter a passcode before viewing the keypad function list menu The system shows the user the menu options allowed according to the user s authority level Passcode controlled menus simplify system operation by providing a user with unique and pertinent options and information This feature is not intended for use on...

Page 11: ...lable The default values for the Bright Dim mode are Bright 10 and Dim 3 On the D1260 and D1260B Keypads when the Sensor Reset command COMMAND 47 is executed Call for Service appears erroneously for a brief time on the display This effect also occurs when the control panel reboots Change the Service Passcode User ID 0 factory default value when the ANSI SIA CP 01 required Passcode Length parameter...

Page 12: ...ccount are armed the keypads in those areas display the text programmed in the Area Acct Is On prompt The control panel is supposed to provide a way to alternately use the display text programmed in the Area is On prompt under the same conditions but this feature is not yet available When an invisible point is programmed with P RlyResp Type set to 2 Relay Latches the relay must be manually reset u...