D7212GV2
D7212GV2 Release Notes for Version 7.07
© 2007 Bosch Security Systems, Inc.
Page 11
F01U009079-04
•
Two new posts next to the on-board telephone
jack allow easy connection of a butt set or
telephone for troubleshooting purposes. The posts
are labeled TIP and RING.
The telephone line supervision time might
be affected when a butt set or telephone is
connected to the telephone terminal posts.
•
On-board Relays B (Terminal 7, labeled Alt
Alarm) and C (Terminal 8, labeled SW Aux) are
now installed in the factory. No supplemental
installation or purchase is necessary to prepare
these terminals for use.
•
The GV2 Series Control Panels now have
integrated watchdog supervision.
•
The battery backed-up RAM now has a device
called a Super-Cap installed. The Super-Cap
maintains power for up to 30 min to the control
panel’s memory when replacing the lithium
battery. In earlier G Series control panels, if the
coin battery was removed and the control panel
was powered down, all configuration was lost.
This enhancement allows the control panel to
retain its configuration during necessary battery
replacement.
5.0
Known Issues
•
When a faulted local point is force armed, the
central station receives a Forced Close Report for
that point. In the current version, the control
panel does not send Forced Close Reports for
faulted local points.
In addition, if both a local and a non-local point
are faulted and force armed, the control panel
does not send Forced Armed, Forced Point, or
Forced Close Reports for the non-local point.
A point is local if it is configured as:
Local While Armed
=
Yes
Local While Disarmed
=
Yes
•
On the D1260 and D1260B Keypads, the
Setup?>
menu under the Service Menu ([9][9] +
[ENTER]), is currently unavailable. The default
values for the Bright Dim mode are Bright = 10
and Dim = 3.
•
On the D1260 and D1260B Keypads, when the
Sensor Reset command (COMMAND 47) is
executed,
Call for Service
appears
erroneously for a brief time on the display. This
effect also occurs when the control panel reboots.
•
Change the Service Passcode (User ID 0) factory
default value when the ANSI SIA CP-01 required
Passcode Length parameter is 4 or greater.
•
The RPS call-back feature using the network is
not available. Leave
GV2AUX
→
SDI RPS
Parameters
→
Call Back Enabled?
at the default
value of
No
when using firmware version 7.05 or
later.
•
The Command 43 RPS connect using network
feature is not available in firmware version 7.05
or later
•
When arming the last associate area from a D1260
or D1260B Keypad, any points that are not ready
to arm in a shared area are automatically
bypassed instead of force bypassed.
•
Using a D1260 Keypad to View Point Status on a
D7212GV2 control panel with firmware versions
7.03, 7.04 or 7.05 firmware causes the keypad to
become unresponsive if any area contains only
one point. You can use
View Point Status
to
scroll through the system’s points until you reach
the point that is the only point in an area. When
you reach this point, the
Previous
and
Next
buttons do not function. If you press the
Exit
button, the system returns to normal operation.
For resolution information, refer to
Unresponsive
D1260 Keypad Technical Bulletin
(P/N: TBI 02-09-
07 01), available on the Bosch Security Systems,
Inc. Web site (www.boschsecurity.us).
•
The
RG#1 Attempt
feature is not available. The
prompts should remain at their default values.
•
With a v7.05 or v7.06 D7212GV2 control panel,
starting and stopping a Fire Walk test command
within the 60-sec Power-up Standby window
causes all 24-hour and fire points within the scope
of the command to be erroneously and
automatically bypassed, regardless of the point’s
configuration.