 D7212GV2 

 

 

  D7212GV2 Release Notes for Version 7.07   

 

© 2007 Bosch Security Systems, Inc. 

Page 11 

F01U009079-04 

 

Two new posts next to the on-board telephone 
jack allow easy connection of a butt set or 
telephone for troubleshooting purposes. The posts 
are labeled TIP and RING. 

 

 

The telephone line supervision time might 
be affected when a butt set or telephone is 
connected to the telephone terminal posts. 

 

On-board Relays B (Terminal 7, labeled Alt 
Alarm) and C (Terminal 8, labeled SW Aux) are 
now installed in the factory. No supplemental 
installation or purchase is necessary to prepare 
these terminals for use. 

 

The GV2 Series Control Panels now have 
integrated watchdog supervision.  

 

The battery backed-up RAM now has a device 
called a Super-Cap installed. The Super-Cap 
maintains power for up to 30 min to the control 
panel’s memory when replacing the lithium 
battery. In earlier G Series control panels, if the 
coin battery was removed and the control panel 
was powered down, all configuration was lost. 
This enhancement allows the control panel to 
retain its configuration during necessary battery 
replacement. 

5.0 

Known Issues  

 

When a faulted local point is force armed, the 
central station receives a Forced Close Report for 
that point. In the current version, the control 
panel does not send Forced Close Reports for 
faulted local points. 

In addition, if both a local and a non-local point 
are faulted and force armed, the control panel 
does not send Forced Armed, Forced Point, or 
Forced Close Reports for the non-local point. 

 

 

A point is local if it is configured as: 

 

Local While Armed

 = 

Yes 

 

Local While Disarmed

 = 

Yes

 

 

On the D1260 and D1260B Keypads, the 

Setup?>

 menu under the Service Menu ([9][9] + 

[ENTER]), is currently unavailable. The default 
values for the Bright Dim mode are Bright = 10 
and Dim = 3. 

 

On the D1260 and D1260B Keypads, when the 
Sensor Reset command (COMMAND 47) is 
executed, 

Call for Service 

appears 

erroneously for a brief time on the display. This 
effect also occurs when the control panel reboots. 

 

Change the Service Passcode (User ID 0) factory 
default value when the ANSI SIA CP-01 required 
Passcode Length parameter is 4 or greater. 

 

The RPS call-back feature using the network is 
not available. Leave 

GV2AUX

SDI RPS 

Parameters

Call Back Enabled?

 at the default 

value of 

No

 when using firmware version  7.05 or 

later. 

 

The Command 43 RPS connect using network 
feature is not available in firmware version  7.05 
or later 

 

When arming the last associate area from a D1260 
or D1260B Keypad, any points that are not ready 
to arm in a shared area are automatically 
bypassed instead of force bypassed. 

 

Using a D1260 Keypad to View Point Status on a 
D7212GV2 control panel with firmware versions 
7.03, 7.04 or 7.05 firmware causes the keypad to 
become unresponsive if any area contains only 
one point. You can use 

View Point Status

 to 

scroll through the system’s points until you reach 
the point that is the only point in an area. When 
you reach this point, the 

Previous

 and 

Next

 

buttons do not function. If you press the 

Exit

 

button, the system returns to normal operation. 
For resolution information, refer to 

Unresponsive 

D1260 Keypad Technical Bulletin

 (P/N: TBI 02-09-

07 01), available on the Bosch Security Systems, 
Inc. Web site (www.boschsecurity.us). 

 

The 

RG#1 Attempt

 feature is not available. The 

prompts should remain at their default values. 

 

With a v7.05 or v7.06 D7212GV2 control panel, 
starting and stopping a Fire Walk test command 
within the 60-sec Power-up Standby window 
causes all 24-hour and fire points within the scope 
of the command to be erroneously and 
automatically bypassed, regardless of the point’s 
configuration. 

 

Summary of Contents for D7212GV2

Page 1: ...07 RADXSKED v1 03 GV2AUX v1 01 Table 2 Supporting Literature for D7212GV2 with Version 7 07 Firmware and Later Document Name Part Number D7212GV2 Program Entry Guide F01U003804 03 D7212GV2 Program Record Sheet F01U003803 03 D7212GV2 Operation and Installation Guide F01U003805 02 D7212GV2 Approved Applications Compliance Guide F01U003806 02 Older revisions have alphabetic revision identifiers for e...

Page 2: ...nt corrupted data account codes for systems that communicate with BIS 2 0 Security Engine These changes are only compatible with BIS Security Engine v2 1 1271 or later This addresses the issues described in the BIS SEE and GV2 G Series Technical Service Note P N F01U073249 Changes made allow the Relay Latches on point fault option for the P Relay Response Type feature to reset when a passcode is e...

Page 3: ... is installed on the RPS workstation special software firewall settings might be required to allow outgoing traffic Refer to your firewall software for configuration information Any DX4020 or D9133TTL E used for enhanced communication to a central station receiver or with RPS over a network must be configured to use Datagram Mode 2 when the control panel firmware is version 7 06 and later Refer to...

Page 4: ...evice are now included when a test report is sent using COMMAND 41 or a sked Corrections enhance the reliability and performance of RPS network connection These corrections also decrease the delay in reporting a break in the Ethernet connection to the control panel s Network Interface Module within the time limits required by UL For UL 1610 Line Security formerly Grade AA Intrusion System installa...

Page 5: ... panel wide Communications Failure Relay output to activate when events in Route Groups 2 through 4 do not reach the central station Previously this relay output activated only on a communication failure for Route Group 1 2 5 Version 7 02 The Phone Line Supervision feature has improved accuracy in detecting the phone line The Modem IIIa2 product ID is changed to the same ID as the G Series control...

Page 6: ...ion This feature was updated to manage the control panel clock adjustments over a period of time instead of simply jumping to the new time This enhancement allows consistent execution of Skeds at their intended times When a TimeSync adjustment is in process the Time Date idle text display is modified with a or sign to indicate control panel time is increasing or decreasing to match the target time...

Page 7: ...ed Fire Bypass Trouble Annunciation The Fire Bypass warning display is modified to generate a Trouble warning tone that can be silenced with COMMAND 4 The trouble condition self clears when all bypassed fire points within the keypad s scope return to service This feature is always on and cannot be disabled Summary Fire Relay Options An option is added that changes the duration of the Panel Wide Su...

Page 8: ...s the Entry Delay starts If the system is not disarmed within the programmed time an Exit Error Alarm is generated This feature is always enabled and has no configuration parameters The alarm with an exit error event creates a new Modem IIIa2 message that the central station might need to add to their automation software Refer to Event 38 in the Modem IIIa2 Messages section of the Appendix in the ...

Page 9: ... after event transmission displays CANCEL RPT SENT on the keypad The burglary alarm cancel window duration is the time programmed in the A Alarm Bell prompt Duress Passcode Prompts Duress Type A Duress Enable L Send Duress A new duress option is available that allows any passcode with the L Send Duress permission set to Yes to always send a Duress Alarm event upon entry This feature allows the con...

Page 10: ...nd simplifies system operation Passcode Controlled Menus The system prompts a user to enter a passcode before viewing the keypad function list menu The system shows the user the menu options allowed according to the user s authority level Passcode controlled menus simplify system operation by providing a user with unique and pertinent options and information This feature is not intended for use on...

Page 11: ...lable The default values for the Bright Dim mode are Bright 10 and Dim 3 On the D1260 and D1260B Keypads when the Sensor Reset command COMMAND 47 is executed Call for Service appears erroneously for a brief time on the display This effect also occurs when the control panel reboots Change the Service Passcode User ID 0 factory default value when the ANSI SIA CP 01 required Passcode Length parameter...

Page 12: ...ccount are armed the keypads in those areas display the text programmed in the Area Acct Is On prompt The control panel is supposed to provide a way to alternately use the display text programmed in the Area is On prompt under the same conditions but this feature is not yet available When an invisible point is programmed with P RlyResp Type set to 2 Relay Latches the relay must be manually reset u...

Reviews: