D7212GV2 

 

 

 D7212GV2 Release Notes for Version 7.07  

 

F01U009079-04 

Page 4 

© 2007 Bosch Security Systems, Inc. 

 

The authority scope problem with the Menu Key 
Lock feature, described in the 

GV2 Series Control 

Panels Menu Key Lock Technical Service Note

 

(P/N: F01U032240), is corrected.  

 

When a user changes the time and date in the 
control panel, the corresponding event now 
reports consistently the identification of the user 
who made the change. 

 

Event reporting for a relay that is set or reset 
using the RPS Diagnostics screen is changed to 
indicate that the operation was done "By 
Programmer" instead of "By Remote.” For 
example, setting a relay with RPS now sends a 

Relay Set by Programmer at SDI 88 

event. 

 

Minor corrections improve the user interface for 
the following function list menus on the D1260 
and D1260B Keypads: 

Master Arm? 
Master Arm Instant? 
Perimeter Arm Delay? 
Perimeter Arm Inst? 
Disarm? 

2.4 Version 

7.03 

 

Changes allow Custom Functions to operate 
correctly in the Function List when 

CC# Menu 

Lock

 is set to 

Yes

 on the D1260 and D1260B 

Keypads. 

 

Corrections disassociate the 

L# Display Revision

 

authority level from the Service Menu on the 
D1260 and D1260B Keypads. 

 

Corrections ensure that the authority level 
permissions of each 

L# Custom Function ###

 

are strictly associated with the correct Custom 
Function number. 

 

If 

Expanded Test Report

 is set to 

Yes

, Summary 

Fire Supervision, Summary Fire Fault, Summary 
Control Point Fault and Summary Point Device 
are now included when a test report is sent using 
COMMAND 41 or a sked. 

 

Corrections enhance the reliability and 
performance of RPS network connection. These 
corrections also decrease the delay in reporting a 
break in the Ethernet connection to the control 
panel’s Network Interface Module within the time 
limits required by UL. 

 

For UL 1610 Line Security (formerly Grade AA) 
Intrusion System installations, use the parameters 
shown in 

Table 4 

on page 4 when configuring the 

Heartbeat Poll. For additional details, refer to 

Programming Path Numbers and IP Addresses for 
Enhanced Communications

  in the 

D7212GV2 

Program Entry Guide

 (P/N: F01U003804). 

 

The recommended settings in 

Table 4

 

(Poll Rate of 75) enable the control panel 
to annunciate locally, within 200 seconds, 
any break in the network communication 
path. 

 

 

Table 4:  Parameters for Heartbeat Poll 

Configuration in Version 7.03

 

Number of 
IP Paths 

Poll Rate 
(sec) 

ACK Wait 
Time (sec) 

Number of 
Retries 

30 

2 to 19 

30 

2 to 12 

30 

10 

2 to 8 

30 

12 

2 to 5 

30 

14 

2 to 3 

60 

2 to 14 

60 

2 to 8 

60 

10 

2 to 5 

60 

12 

1 75

2

 10

2

 

3

2

 

90 

2 to 9 

90 

2 to 4 

90 

10 

120 

2 to 4 

145 

2 75

2

 

8

2

 

3

2

 

75

2

 

6

2

 

3

2

 

4 75

2

 

5

2

 

3

2

 

1

  The parameters in this table are for Version 7.03 

only

2

  Recommended settings for the corresponding number 

of IP paths. 

 

Corrections allow the 

Path # Retry Count

 value 

to be used as the number of retries instead of the 
number of transmission attempts. 

 

When the control panel disconnects from an RPS 
session using the network, and the “Reset Panel” 
checkbox is set, the control panel now logs a 
Remote Reset event instead of a Reboot Event. 

Summary of Contents for D7212GV2

Page 1: ...07 RADXSKED v1 03 GV2AUX v1 01 Table 2 Supporting Literature for D7212GV2 with Version 7 07 Firmware and Later Document Name Part Number D7212GV2 Program Entry Guide F01U003804 03 D7212GV2 Program Record Sheet F01U003803 03 D7212GV2 Operation and Installation Guide F01U003805 02 D7212GV2 Approved Applications Compliance Guide F01U003806 02 Older revisions have alphabetic revision identifiers for e...

Page 2: ...nt corrupted data account codes for systems that communicate with BIS 2 0 Security Engine These changes are only compatible with BIS Security Engine v2 1 1271 or later This addresses the issues described in the BIS SEE and GV2 G Series Technical Service Note P N F01U073249 Changes made allow the Relay Latches on point fault option for the P Relay Response Type feature to reset when a passcode is e...

Page 3: ... is installed on the RPS workstation special software firewall settings might be required to allow outgoing traffic Refer to your firewall software for configuration information Any DX4020 or D9133TTL E used for enhanced communication to a central station receiver or with RPS over a network must be configured to use Datagram Mode 2 when the control panel firmware is version 7 06 and later Refer to...

Page 4: ...evice are now included when a test report is sent using COMMAND 41 or a sked Corrections enhance the reliability and performance of RPS network connection These corrections also decrease the delay in reporting a break in the Ethernet connection to the control panel s Network Interface Module within the time limits required by UL For UL 1610 Line Security formerly Grade AA Intrusion System installa...

Page 5: ... panel wide Communications Failure Relay output to activate when events in Route Groups 2 through 4 do not reach the central station Previously this relay output activated only on a communication failure for Route Group 1 2 5 Version 7 02 The Phone Line Supervision feature has improved accuracy in detecting the phone line The Modem IIIa2 product ID is changed to the same ID as the G Series control...

Page 6: ...ion This feature was updated to manage the control panel clock adjustments over a period of time instead of simply jumping to the new time This enhancement allows consistent execution of Skeds at their intended times When a TimeSync adjustment is in process the Time Date idle text display is modified with a or sign to indicate control panel time is increasing or decreasing to match the target time...

Page 7: ...ed Fire Bypass Trouble Annunciation The Fire Bypass warning display is modified to generate a Trouble warning tone that can be silenced with COMMAND 4 The trouble condition self clears when all bypassed fire points within the keypad s scope return to service This feature is always on and cannot be disabled Summary Fire Relay Options An option is added that changes the duration of the Panel Wide Su...

Page 8: ...s the Entry Delay starts If the system is not disarmed within the programmed time an Exit Error Alarm is generated This feature is always enabled and has no configuration parameters The alarm with an exit error event creates a new Modem IIIa2 message that the central station might need to add to their automation software Refer to Event 38 in the Modem IIIa2 Messages section of the Appendix in the ...

Page 9: ... after event transmission displays CANCEL RPT SENT on the keypad The burglary alarm cancel window duration is the time programmed in the A Alarm Bell prompt Duress Passcode Prompts Duress Type A Duress Enable L Send Duress A new duress option is available that allows any passcode with the L Send Duress permission set to Yes to always send a Duress Alarm event upon entry This feature allows the con...

Page 10: ...nd simplifies system operation Passcode Controlled Menus The system prompts a user to enter a passcode before viewing the keypad function list menu The system shows the user the menu options allowed according to the user s authority level Passcode controlled menus simplify system operation by providing a user with unique and pertinent options and information This feature is not intended for use on...

Page 11: ...lable The default values for the Bright Dim mode are Bright 10 and Dim 3 On the D1260 and D1260B Keypads when the Sensor Reset command COMMAND 47 is executed Call for Service appears erroneously for a brief time on the display This effect also occurs when the control panel reboots Change the Service Passcode User ID 0 factory default value when the ANSI SIA CP 01 required Passcode Length parameter...

Page 12: ...ccount are armed the keypads in those areas display the text programmed in the Area Acct Is On prompt The control panel is supposed to provide a way to alternately use the display text programmed in the Area is On prompt under the same conditions but this feature is not yet available When an invisible point is programmed with P RlyResp Type set to 2 Relay Latches the relay must be manually reset u...