D7212GV2 Release Notes for Version 7.07
F01U009079-04
Page 4
© 2007 Bosch Security Systems, Inc.
•
The authority scope problem with the Menu Key
Lock feature, described in the
GV2 Series Control
Panels Menu Key Lock Technical Service Note
(P/N: F01U032240), is corrected.
•
When a user changes the time and date in the
control panel, the corresponding event now
reports consistently the identification of the user
who made the change.
•
Event reporting for a relay that is set or reset
using the RPS Diagnostics screen is changed to
indicate that the operation was done "By
Programmer" instead of "By Remote.” For
example, setting a relay with RPS now sends a
Relay Set by Programmer at SDI 88
event.
•
Minor corrections improve the user interface for
the following function list menus on the D1260
and D1260B Keypads:
Master Arm?
Master Arm Instant?
Perimeter Arm Delay?
Perimeter Arm Inst?
Disarm?
2.4 Version
7.03
•
Changes allow Custom Functions to operate
correctly in the Function List when
CC# Menu
Lock
is set to
Yes
on the D1260 and D1260B
Keypads.
•
Corrections disassociate the
L# Display Revision
authority level from the Service Menu on the
D1260 and D1260B Keypads.
•
Corrections ensure that the authority level
permissions of each
L# Custom Function ###
are strictly associated with the correct Custom
Function number.
•
If
Expanded Test Report
is set to
Yes
, Summary
Fire Supervision, Summary Fire Fault, Summary
Control Point Fault and Summary Point Device
are now included when a test report is sent using
COMMAND 41 or a sked.
•
Corrections enhance the reliability and
performance of RPS network connection. These
corrections also decrease the delay in reporting a
break in the Ethernet connection to the control
panel’s Network Interface Module within the time
limits required by UL.
•
For UL 1610 Line Security (formerly Grade AA)
Intrusion System installations, use the parameters
shown in
Table 4
on page 4 when configuring the
Heartbeat Poll. For additional details, refer to
Programming Path Numbers and IP Addresses for
Enhanced Communications
in the
D7212GV2
Program Entry Guide
(P/N: F01U003804).
The recommended settings in
Table 4
(Poll Rate of 75) enable the control panel
to annunciate locally, within 200 seconds,
any break in the network communication
path.
Table 4: Parameters for Heartbeat Poll
Configuration in Version 7.03
1
Number of
IP Paths
Poll Rate
(sec)
ACK Wait
Time (sec)
Number of
Retries
1
30
6
2 to 19
1
30
8
2 to 12
1
30
10
2 to 8
1
30
12
2 to 5
1
30
14
2 to 3
1
60
6
2 to 14
1
60
8
2 to 8
1
60
10
2 to 5
1
60
12
2
1 75
2
10
2
3
2
1
90
6
2 to 9
1
90
8
2 to 4
1
90
10
2
1
120
6
2 to 4
1
145
5
2
2 75
2
8
2
3
2
3
75
2
6
2
3
2
4 75
2
5
2
3
2
1
The parameters in this table are for Version 7.03
only
.
2
Recommended settings for the corresponding number
of IP paths.
•
Corrections allow the
Path # Retry Count
value
to be used as the number of retries instead of the
number of transmission attempts.
•
When the control panel disconnects from an RPS
session using the network, and the “Reset Panel”
checkbox is set, the control panel now logs a
Remote Reset event instead of a Reboot Event.