  D7212GV2 Release Notes for Version 7.07   

 

© 2007 Bosch Security Systems, Inc. 

Page 5 

F01U009079-04 

 

Corrections now prevent the D7212GV2 Control 
Panel from performing a watchdog reset when an 
area with an 

A # Area Type

 set to 

Shared

 is 

individually armed. Shared areas should not be 
individually armed or disarmed. 

 

Corrections now prevent a duress passcode from 
being accepted by a keypad currently in an area 
that has 

A# Duress Enable

 set to 

No

. If the 

Duress feature is used, A

# Duress Enable

 should 

be set to 

Yes

 for all areas. 

 

The alternate function of Area 6 Silent Alarm 
Relay parameter was removed. To enable Fire 
Trouble Resound support, use 

GV2AUX

MISCELLANEOUS

Fire Trouble 

Resound

.

 

 

The alternate function of Area 5 Silent Alarm 
Relay parameter was removed. The Ground Fault 
detection feature is solely enabled by closing 
Switch S4 on the D7212GV2 Control Panel. 

 

Changes now suppress the 

ALARM SILENCED

 

message when a user attempts to silence a Ring 
Until Restored fire bell. A fire alarm generated by 
a point with the Ring Until Restored (

P# Ring Til 

Rst

) feature set to 

Yes

 will sustain the fire bell 

until the sensor is restored. 

 

Corrections ensure that acknowledged Silent 
Alarms scroll correctly on the idle text displays on 
the D1260 and D1260B Keypads. 

 

Corrections now allow a user’s token, with 

L# 

Disarm Level

 set to 

I

, to disarm the interior of all 

areas within the scope of the keypad programmed 
at 

D# CC# Scope

. The keypad programmed at 

D# CC# Scope

 must have 

CC# Passcode 

Follows Scope

 set to 

Yes

 to disarm the interior of 

all areas within scope. 

 

Corrections now allow the panel-wide 
Communications Failure Relay output to activate 
when events in Route Groups 2 through 4 do not 
reach the central station. Previously this relay 
output activated only on a communication failure 
for Route Group 1. 

2.5 Version 

7.02 

 

The Phone Line Supervision feature has improved 
accuracy in detecting the phone line. 

 

The Modem IIIa

2

 product ID is changed to the 

same ID as the G Series control panels, allowing 
compatibility with non-Bosch central station 
receivers. 

2.6 Version 

7.01 

The following are corrections and changes made since 
Version 6.60 in the G Series Control Panels. 

 

The GV2 Series Control Panels have the same 
response to low AC voltage as to an AC failure. 

 

If the control panel battery is detected as missing, 
the Walk Test function skips the Battery Test. 

 

Several system stability issues are fixed to prevent 
erroneous Parameter Checksum Failures. 

 

The Service Walk Test on the D7212GV2 now 
shows the correct maximum number of points in 
the system. 

 

The Telephone Ground Start circuitry and 
associated programming prompts are removed 
from the GV2 Series Control Panels. 

 

The GV2 Series Control Panels require the D6500 
receiver to have a D6511 MPU card at version 
1.06 or above for maximum communication 
efficiency. 

 

The Extend Close (COMMAND 51) feature was 
modified to prevent the new Close Window time 
from setting to a value earlier than the current 
time. 

 

When disarming an area with 

Two Man Rule

 

enabled, the keypad waits for the time equal to 
the exit delay for the area. If the second passcode 
is not entered before the prompt times out, then 
the rule resets and waits for the first passcode 
again. 

 

Several changes in this release prevent local alarm 
events from being sent intermittently to the 
central station. All local alarm events should now 
remain local. 

Summary of Contents for D7212GV2

Page 1: ...07 RADXSKED v1 03 GV2AUX v1 01 Table 2 Supporting Literature for D7212GV2 with Version 7 07 Firmware and Later Document Name Part Number D7212GV2 Program Entry Guide F01U003804 03 D7212GV2 Program Record Sheet F01U003803 03 D7212GV2 Operation and Installation Guide F01U003805 02 D7212GV2 Approved Applications Compliance Guide F01U003806 02 Older revisions have alphabetic revision identifiers for e...

Page 2: ...nt corrupted data account codes for systems that communicate with BIS 2 0 Security Engine These changes are only compatible with BIS Security Engine v2 1 1271 or later This addresses the issues described in the BIS SEE and GV2 G Series Technical Service Note P N F01U073249 Changes made allow the Relay Latches on point fault option for the P Relay Response Type feature to reset when a passcode is e...

Page 3: ... is installed on the RPS workstation special software firewall settings might be required to allow outgoing traffic Refer to your firewall software for configuration information Any DX4020 or D9133TTL E used for enhanced communication to a central station receiver or with RPS over a network must be configured to use Datagram Mode 2 when the control panel firmware is version 7 06 and later Refer to...

Page 4: ...evice are now included when a test report is sent using COMMAND 41 or a sked Corrections enhance the reliability and performance of RPS network connection These corrections also decrease the delay in reporting a break in the Ethernet connection to the control panel s Network Interface Module within the time limits required by UL For UL 1610 Line Security formerly Grade AA Intrusion System installa...

Page 5: ... panel wide Communications Failure Relay output to activate when events in Route Groups 2 through 4 do not reach the central station Previously this relay output activated only on a communication failure for Route Group 1 2 5 Version 7 02 The Phone Line Supervision feature has improved accuracy in detecting the phone line The Modem IIIa2 product ID is changed to the same ID as the G Series control...

Page 6: ...ion This feature was updated to manage the control panel clock adjustments over a period of time instead of simply jumping to the new time This enhancement allows consistent execution of Skeds at their intended times When a TimeSync adjustment is in process the Time Date idle text display is modified with a or sign to indicate control panel time is increasing or decreasing to match the target time...

Page 7: ...ed Fire Bypass Trouble Annunciation The Fire Bypass warning display is modified to generate a Trouble warning tone that can be silenced with COMMAND 4 The trouble condition self clears when all bypassed fire points within the keypad s scope return to service This feature is always on and cannot be disabled Summary Fire Relay Options An option is added that changes the duration of the Panel Wide Su...

Page 8: ...s the Entry Delay starts If the system is not disarmed within the programmed time an Exit Error Alarm is generated This feature is always enabled and has no configuration parameters The alarm with an exit error event creates a new Modem IIIa2 message that the central station might need to add to their automation software Refer to Event 38 in the Modem IIIa2 Messages section of the Appendix in the ...

Page 9: ... after event transmission displays CANCEL RPT SENT on the keypad The burglary alarm cancel window duration is the time programmed in the A Alarm Bell prompt Duress Passcode Prompts Duress Type A Duress Enable L Send Duress A new duress option is available that allows any passcode with the L Send Duress permission set to Yes to always send a Duress Alarm event upon entry This feature allows the con...

Page 10: ...nd simplifies system operation Passcode Controlled Menus The system prompts a user to enter a passcode before viewing the keypad function list menu The system shows the user the menu options allowed according to the user s authority level Passcode controlled menus simplify system operation by providing a user with unique and pertinent options and information This feature is not intended for use on...

Page 11: ...lable The default values for the Bright Dim mode are Bright 10 and Dim 3 On the D1260 and D1260B Keypads when the Sensor Reset command COMMAND 47 is executed Call for Service appears erroneously for a brief time on the display This effect also occurs when the control panel reboots Change the Service Passcode User ID 0 factory default value when the ANSI SIA CP 01 required Passcode Length parameter...

Page 12: ...ccount are armed the keypads in those areas display the text programmed in the Area Acct Is On prompt The control panel is supposed to provide a way to alternately use the display text programmed in the Area is On prompt under the same conditions but this feature is not yet available When an invisible point is programmed with P RlyResp Type set to 2 Relay Latches the relay must be manually reset u...

Reviews: