 D7212GV2 Release Notes for Version 7.07  

 

F01U009079-04 

Page 6 

© 2007 Bosch Security Systems, Inc. 

3.0 New 

Features 

3.1 Version 

7.07 

 

Enhanced Communication Path Port 
Numbers:

 A new prompt was added to each of 

the four enhanced communication paths (

Path # 

Port Num

) to specify an individual destination 

port number. All four IP/port pairs must be 
unique to ensure event acknowledgements are 
accounted for correctly. Duplicate IP address/port 
pairs can cause unreliable communication. This 
enhancement further facilitates the Port Address 
Translation feature added in V7.06. When 
upgrading from V7.06 or later, these prompts are 
set to 

0000

, which is treated as if set to the default 

value of 

7700

 

RPS Port Number:

 The 

Base Port Number

 

prompt was renamed 

RPS Port Number

 to 

distinguish it from the Enhanced Communication 
Path Port Number prompts. This prompt 
continues to provide the destination port for 
network RPS sessions initiated by the control 
panel. 

 

Anti-substitution Enhancement: 

The anti-

replay, or anti-panel-substitution, feature was 
enhanced to allow simultaneous multiple 
enhanced communication paths. Previously, only 
one path could be enabled when the 

EnableAntireplay 

prompt was set to 

Yes

. Now, 

each destination path has its own 

Path 

#AntiReplay

 prompt, and multiple paths can be 

enabled. 

 

 

When RPS v5.7 or later, or GV2AUX 
v1.03 or later, sends data to a D7212GV2 
control panel running v7.06 or earlier, use 
the 

Path 1AntiReplay

 prompt to enable 

the Anti-Replay feature. 

 

Time Sync Enhancements: 

The Time Sync 

feature is used by the D6600 receiver to update 
the minutes of the hour in the control panel clock 
to keep it synchronized with the time at the 
central station. This feature was updated to 
manage the control panel clock adjustments over 
a period of time instead of simply jumping to the 
new time. This enhancement allows consistent 
execution of Skeds at their intended times. When 
a TimeSync adjustment is in process, the 
Time/Date idle text display is modified with a ‘+’ 
or ‘-’ sign to indicate control panel time is 
increasing or decreasing to match the target time. 

When a TimeSync adjustment completes, the 
control panel sends a Time Change event as User 
254. This feature is enabled and disabled at the 
D6600 receiver, and cannot be controlled by the 
control panel. 

 

If the control panel is configured to send 
to multiple D6600 receivers using 
enhanced communication paths, enable 
Time Sync in only one receiver account. 

 

Local AC Failure Annunciation:

 Changes were 

made to delay the keypad AC Failure display by 
the amount of time programmed in 

AC Fail 

Display

 prompt after the main line AC is lost. 

The same delay is used to hold off clearing the 
display when the AC returns. The AC failure 
report and AC failure relay still follow the delay 
programmed in 

AC Fail Time

3.2 

Version 7.05 – UL and ANSI/ 
SIA CP-01 Compliance 

3.2.1 UL 

Compliance 

 

 

Version 7.04 was skipped during 
development and was not released.  

 

 

The D7212GV2 is not approved for 
Commercial Fire. 

Support for D1255RB and D1256RB Keypads, and 
D1257RB Annunciator 

The D7212GV2 Control Panels, version 7.05 and 
above, support the new D1255RB and D1256 
Keypads and the new D1257RB Annunciator. These 
new devices have four LEDs added to indicate Fire 
Alarm, Trouble, Supervisory, and Alarm Silenced. 
This LED feature is enabled automatically when a 
D125xRB device is installed. Refer to the 

D7212GV2 

Program Entry Guide

 (P/N: F01U003804-02 or later). 

Previous versions of the program entry guide, with 
alphabetic revision identifiers, do not include 
information related to the D125xRB devices. 

Summary of Contents for D7212GV2

Page 1: ...07 RADXSKED v1 03 GV2AUX v1 01 Table 2 Supporting Literature for D7212GV2 with Version 7 07 Firmware and Later Document Name Part Number D7212GV2 Program Entry Guide F01U003804 03 D7212GV2 Program Record Sheet F01U003803 03 D7212GV2 Operation and Installation Guide F01U003805 02 D7212GV2 Approved Applications Compliance Guide F01U003806 02 Older revisions have alphabetic revision identifiers for e...

Page 2: ...nt corrupted data account codes for systems that communicate with BIS 2 0 Security Engine These changes are only compatible with BIS Security Engine v2 1 1271 or later This addresses the issues described in the BIS SEE and GV2 G Series Technical Service Note P N F01U073249 Changes made allow the Relay Latches on point fault option for the P Relay Response Type feature to reset when a passcode is e...

Page 3: ... is installed on the RPS workstation special software firewall settings might be required to allow outgoing traffic Refer to your firewall software for configuration information Any DX4020 or D9133TTL E used for enhanced communication to a central station receiver or with RPS over a network must be configured to use Datagram Mode 2 when the control panel firmware is version 7 06 and later Refer to...

Page 4: ...evice are now included when a test report is sent using COMMAND 41 or a sked Corrections enhance the reliability and performance of RPS network connection These corrections also decrease the delay in reporting a break in the Ethernet connection to the control panel s Network Interface Module within the time limits required by UL For UL 1610 Line Security formerly Grade AA Intrusion System installa...

Page 5: ... panel wide Communications Failure Relay output to activate when events in Route Groups 2 through 4 do not reach the central station Previously this relay output activated only on a communication failure for Route Group 1 2 5 Version 7 02 The Phone Line Supervision feature has improved accuracy in detecting the phone line The Modem IIIa2 product ID is changed to the same ID as the G Series control...

Page 6: ...ion This feature was updated to manage the control panel clock adjustments over a period of time instead of simply jumping to the new time This enhancement allows consistent execution of Skeds at their intended times When a TimeSync adjustment is in process the Time Date idle text display is modified with a or sign to indicate control panel time is increasing or decreasing to match the target time...

Page 7: ...ed Fire Bypass Trouble Annunciation The Fire Bypass warning display is modified to generate a Trouble warning tone that can be silenced with COMMAND 4 The trouble condition self clears when all bypassed fire points within the keypad s scope return to service This feature is always on and cannot be disabled Summary Fire Relay Options An option is added that changes the duration of the Panel Wide Su...

Page 8: ...s the Entry Delay starts If the system is not disarmed within the programmed time an Exit Error Alarm is generated This feature is always enabled and has no configuration parameters The alarm with an exit error event creates a new Modem IIIa2 message that the central station might need to add to their automation software Refer to Event 38 in the Modem IIIa2 Messages section of the Appendix in the ...

Page 9: ... after event transmission displays CANCEL RPT SENT on the keypad The burglary alarm cancel window duration is the time programmed in the A Alarm Bell prompt Duress Passcode Prompts Duress Type A Duress Enable L Send Duress A new duress option is available that allows any passcode with the L Send Duress permission set to Yes to always send a Duress Alarm event upon entry This feature allows the con...

Page 10: ...nd simplifies system operation Passcode Controlled Menus The system prompts a user to enter a passcode before viewing the keypad function list menu The system shows the user the menu options allowed according to the user s authority level Passcode controlled menus simplify system operation by providing a user with unique and pertinent options and information This feature is not intended for use on...

Page 11: ...lable The default values for the Bright Dim mode are Bright 10 and Dim 3 On the D1260 and D1260B Keypads when the Sensor Reset command COMMAND 47 is executed Call for Service appears erroneously for a brief time on the display This effect also occurs when the control panel reboots Change the Service Passcode User ID 0 factory default value when the ANSI SIA CP 01 required Passcode Length parameter...

Page 12: ...ccount are armed the keypads in those areas display the text programmed in the Area Acct Is On prompt The control panel is supposed to provide a way to alternately use the display text programmed in the Area is On prompt under the same conditions but this feature is not yet available When an invisible point is programmed with P RlyResp Type set to 2 Relay Latches the relay must be manually reset u...

Reviews: