 D7212GV2 Release Notes for Version 7.07  

 

F01U009079-04 

Page 10 

© 2007 Bosch Security Systems, Inc. 

3.3 Version 

7.01 

3.3.1 

D1260 Keypad Enhancements 

The D1260 Keypad 

must have

 firmware version 1.03 

or above to operate with the GV2 Series Control 
Panels. 

An update kit (P/N: R19-D1260-0103) is 

available from Customer Service: (800) 289-0096.

 

Custom Function Enhancements

: The custom 

functions now support the soft keys (the eight 
unmarked keys around the display) on the D1260 
Keypad. This change makes the operation of custom 
functions on D1260 Keypad easier to program. 

D1260 Keypads with firmware version 1.03 or above 
do not need to check the control panel firmware 
revision when communicating with GV2 Series 
Control Panels; therefore, the Display Revision 
(COMMAND 59) keypad (command center) function 
can be password protected. 

3.3.2 

New Firmware Features: 

Two Man Rule: 

Two Man Rule requires two unique 

passcodes to be entered at the same keypad to disarm 
an area. Without the second passcode, the system 
denies entry. Two Man Rule requires the presence of 
two people at opening, providing added security. 

Early Ambush

: Early Ambush requires two passcode 

entries on the same keypad or on two separate 
keypads located in the same area. Enter the same 
passcode twice or enter two unique passcodes, 
depending upon the configuration. The first entry 
disarms the area and the second entry stops a timer 
programmed to send a duress event. If the second 
entry does not occur within the preset time, the 
system generates a duress event. Early Ambush allows 
users to inspect the premises and use the system to 
confirm that the area is safe to enter, providing added 
security. 

Easy Exit Control:

 The D7212GV2 changes from 

one armed state to another armed state without 
disarming. For example, if you change the state from 
Master Arm to Perimeter Arm, the control panel 
complies and reports the change. Easy Exit Control 
reduces the number of keystrokes and simplifies 
system operation. 

Passcode-Controlled Menus

: The system prompts a 

user to enter a passcode before viewing the keypad 
function list menu. The system shows the user the 
menu options allowed according to the user’s 
authority level. Passcode-controlled menus simplify 
system operation by providing a user with unique and 
pertinent options and information. This feature is not 
intended for use on D1256 Fire Keypads. 

Passcode Follows Scope:

 Use Passcode Follows 

Scope to restrict passcode arming and disarming only 
to the keypad’s immediate local area. Passcode 
Follows Scope simplifies the arming and disarming 
procedure without limiting any other keypad 
command capabilities. 

Invisible Walk Test:

 A function list menu item 

allows the user to test invisible interior or perimeter 
controlled and non-controlled (24-hr) points within the 
scope of the keypad without sending a report to the 
central station. 

Latest Close Time

: The Extend Close  

(COMMAND 51) function is enhanced with a 
programmable latest closing time. 

4.0 

Upgrading to a GV2 Series 
Control Panel 

Remote Programming Software (RPS) version 3.7.160 
or above is required to upgrade an existing G Series 
Control Panel installation to a GV2 Series Control 
Panel. Because the GV2MAIN and GV2AUX 
handlers cannot read the configuration data from a 
G Series Control Panel, using RPS is the only method 
available to convert an account’s existing panel type 
to a D7212GV2. 

Refer to the RPS Help files for the specific control 
panel for additional information on control panel 
conversion. In the RPS help file, select:  

Panel Specific Information

Æ

9000 Series 

Control/Communicators

Æ

Communicating with 

9000 Series Panels

Æ

Upgrading a Panel Type 

Hardware Enhancements 

 

The control panel has an SDI bus quick-connect 
terminal (Molex

®

 connector) next to the S1 reset 

switch. This connector provides an easy way to 
connect an SDI device to the SDI bus without 
disconnecting the wires on SDI Terminals 29 
through 32. To order SDI wiring harnesses, use 
the following part numbers: Molex

®

 to Molex

®

  

(P/N: C321) and Molex

®

 to terminal  

(P/N: PKWH). 

 

This SDI terminal 

is not compatible

 with 

the D5200 Programmer. 

 

Summary of Contents for D7212GV2

Page 1: ...07 RADXSKED v1 03 GV2AUX v1 01 Table 2 Supporting Literature for D7212GV2 with Version 7 07 Firmware and Later Document Name Part Number D7212GV2 Program Entry Guide F01U003804 03 D7212GV2 Program Record Sheet F01U003803 03 D7212GV2 Operation and Installation Guide F01U003805 02 D7212GV2 Approved Applications Compliance Guide F01U003806 02 Older revisions have alphabetic revision identifiers for e...

Page 2: ...nt corrupted data account codes for systems that communicate with BIS 2 0 Security Engine These changes are only compatible with BIS Security Engine v2 1 1271 or later This addresses the issues described in the BIS SEE and GV2 G Series Technical Service Note P N F01U073249 Changes made allow the Relay Latches on point fault option for the P Relay Response Type feature to reset when a passcode is e...

Page 3: ... is installed on the RPS workstation special software firewall settings might be required to allow outgoing traffic Refer to your firewall software for configuration information Any DX4020 or D9133TTL E used for enhanced communication to a central station receiver or with RPS over a network must be configured to use Datagram Mode 2 when the control panel firmware is version 7 06 and later Refer to...

Page 4: ...evice are now included when a test report is sent using COMMAND 41 or a sked Corrections enhance the reliability and performance of RPS network connection These corrections also decrease the delay in reporting a break in the Ethernet connection to the control panel s Network Interface Module within the time limits required by UL For UL 1610 Line Security formerly Grade AA Intrusion System installa...

Page 5: ... panel wide Communications Failure Relay output to activate when events in Route Groups 2 through 4 do not reach the central station Previously this relay output activated only on a communication failure for Route Group 1 2 5 Version 7 02 The Phone Line Supervision feature has improved accuracy in detecting the phone line The Modem IIIa2 product ID is changed to the same ID as the G Series control...

Page 6: ...ion This feature was updated to manage the control panel clock adjustments over a period of time instead of simply jumping to the new time This enhancement allows consistent execution of Skeds at their intended times When a TimeSync adjustment is in process the Time Date idle text display is modified with a or sign to indicate control panel time is increasing or decreasing to match the target time...

Page 7: ...ed Fire Bypass Trouble Annunciation The Fire Bypass warning display is modified to generate a Trouble warning tone that can be silenced with COMMAND 4 The trouble condition self clears when all bypassed fire points within the keypad s scope return to service This feature is always on and cannot be disabled Summary Fire Relay Options An option is added that changes the duration of the Panel Wide Su...

Page 8: ...s the Entry Delay starts If the system is not disarmed within the programmed time an Exit Error Alarm is generated This feature is always enabled and has no configuration parameters The alarm with an exit error event creates a new Modem IIIa2 message that the central station might need to add to their automation software Refer to Event 38 in the Modem IIIa2 Messages section of the Appendix in the ...

Page 9: ... after event transmission displays CANCEL RPT SENT on the keypad The burglary alarm cancel window duration is the time programmed in the A Alarm Bell prompt Duress Passcode Prompts Duress Type A Duress Enable L Send Duress A new duress option is available that allows any passcode with the L Send Duress permission set to Yes to always send a Duress Alarm event upon entry This feature allows the con...

Page 10: ...nd simplifies system operation Passcode Controlled Menus The system prompts a user to enter a passcode before viewing the keypad function list menu The system shows the user the menu options allowed according to the user s authority level Passcode controlled menus simplify system operation by providing a user with unique and pertinent options and information This feature is not intended for use on...

Page 11: ...lable The default values for the Bright Dim mode are Bright 10 and Dim 3 On the D1260 and D1260B Keypads when the Sensor Reset command COMMAND 47 is executed Call for Service appears erroneously for a brief time on the display This effect also occurs when the control panel reboots Change the Service Passcode User ID 0 factory default value when the ANSI SIA CP 01 required Passcode Length parameter...

Page 12: ...ccount are armed the keypads in those areas display the text programmed in the Area Acct Is On prompt The control panel is supposed to provide a way to alternately use the display text programmed in the Area is On prompt under the same conditions but this feature is not yet available When an invisible point is programmed with P RlyResp Type set to 2 Relay Latches the relay must be manually reset u...

Reviews: