Specifications
Dimensions
(H x W x D)
D6600
Rack mount (4U)
18 cm x 48.3 cm x 49.5 cm
(7.0 in x 19.0 in x 19.5 in)
Standalone
18 cm x 45.0 cm x 49.5 cm
(7.0 in x 17.75 i. x 19.5 in)
D6100IPv6
Rack mount (2U)
9.0 cm. x 37.5 cm. x 25.5 cm
(3.5 in x 19 in x 10 in)
Standalone
9.0 cm. x 30.5 cm. x 25.5 cm
(3.5 in x 12.0 in x 10 in)
Weight
D6600
8.7 kg (19 lb)
D6100IPv6
3 kg (7 lb)
AC Nominal Operating
Range
120 V or 230 V
AC Maximum Operating
Range
100 VAC to 120 VAC, 220 VAC to 240 VAC, 50 - 60 Hz
2.5 A maximum
Power Cord
IEC 60320 C13 type
Replaceable Fuse
2.5A F250V fast blow 5x20mm
D6100IPv6 Power Input
AC Nominal Operating
Range
18VAC (see specific Installation Supplement supplied
with your product for your application for supplied
transformer specifics)
Current Required
D6600 with one line card
installed
Required battery current
800 mA
Required UPS AC standby current
350 mA
For each additional line card
or terminal card pair
Required additional battery current 210 mA
Required additional UPS AC
standby current
35 mA
For network
communications card
Required additional battery current 10 mA
Required additional UPS AC
standby current
10 mA
D6100IPv6
Required battery current
330 mA
Required UPS AC standby current
250 mA
Standby Power
The receiver includes an external battery connection and battery harness. Use 12 V
rechargeable sealed lead-acid batteries.
Standby power supply (UPS or battery) requirements: 24-hour minimum for UL Fire
applications (UL864); 4‑hour minimum for UL Burglary applications (UL1610).
Refer to Connecting External Batteries, page 27 for battery size.
Telephone
RJ11C modular jacks, with 26 AWG or larger wire diameter.
17
80
en | Specifications
Conettix Communications Receiver/
Gateway
2012.11 | 08 | 4998122704
Installation and Operation Guide
Bosch Security Systems, Inc.
Summary of Contents for Conettix D6100IPv6
Page 1: ...Conettix Communications Receiver Gate way D6600 D6100IPv6 en Installation and Operation Guide ...
Page 2: ......
Page 86: ......