Config
Section
Config
Sub-
section
Config
Parameter
Default
Value
Valid Values
Description
interface
eth0
default
gateway
<None
>
Accepts in
IPv4 address
in dotted
notation
(192.168.1.1)
If IPv4 DHCP is disabled, enter the IPv4
Gateway IP Address.
interface
eth0
dhcpv6
enable
enable, disable Determines if IPv6 DHCP is used. If this is set
to disabled, then a Static IPv6 Address needs
to be specified in the IP Address
Configuration Parameter.
interface
eth0
ipv6
address
<None
>
Accepts an
IPv6 address
If IPv6 DHCP is disabled, then an IPv6
Address must be entered here.
interface
eth0
ipv6
default
gateway
<None
>
Accepts an
IPv6 address
in colon
notation
(2001:0db8:85
a3:0042:0000:
8a2e:
0370:7334)
If IPv6 DHCP is disabled, enter the IPv6
Gateway IP Address.
interface
eth0
hostname
Sets the hostname that is used with DHCP.
oem
mac
address
Allows for an alternate MAC Address to be
entered here supporting the failover
configuration described in the D6600/
D6100IPv6 I&O Guide (4998122704).
device
short
name
D6686
Sets the product short name displayed in
command mode. (Max of 8 Characters)
device
long name Bosch
D6686
Sets the product long name displayed in
command mode.
bosch tunnel
1 or 2
local port
7700
(tunnel
1) / 7701
(tunnel 2)
IP Port number the D6686 is listening on for
IP traffic relative to each serial port. See the
failover configuration described in the D6600/
D6100IPv6 I&O Guide (4998122704).
bosch tunnel
1 or 2
protocol
UDP
UDP, UDP AES Determines the protocol to be used
depending whether encryption is being used.
(See Important Note on next page)
bosch tunnel
1 or 2
aes key
size
128
128, 192, 256
Determines the Encryption Key Size in
number of bits.
62
en | Network Communications
Conettix Communications Receiver/
Gateway
2012.11 | 08 | 4998122704
Installation and Operation Guide
Bosch Security Systems, Inc.
Summary of Contents for Conettix D6100IPv6
Page 1: ...Conettix Communications Receiver Gate way D6600 D6100IPv6 en Installation and Operation Guide ...
Page 2: ......
Page 86: ......
Page 87: ......