Bosch Power Tec GmbH
Storage system |
User manual
En
g
lis
h
DO_BA_2013_H
Y
B
_A_3ENG_BBo
17.01
.2014
English
Specifications | 81
Expected service life
15 years (4.4 kWh system)
15 years (6.6 kWh system)
20 years (8.8 kWh system)
20 years (11 kWh system)
20 years (13.2 kWh system)
Max. charging and discharging power
2.5 kW (4.4 kWh system)
3.75 kW (6.6 kWh system)
5 kW (8.8 kWh system)
5 kW (11 kWh system)
5 kW (13.2 kWh system)
Emergency power supply
Compatible with emergency power
restricted: only with existing
PV power (4.4/6.6 kWh
system)
yes (8.8 kWh system)
yes (11 kWh system)
yes (13.2 kWh system)
Rated voltage
230 V
Rated current
13 A
Max. output current
22 A
Max. output power
2.5 kW (4.4 kWh system)
3.75 kW (6.6 kWh system)
5 kW (8.8 kWh system)
5 kW (11 kWh system)
5 kW (13.2 kWh system)
Rated frequency (f
r
)
50 Hz
Emergency power relay control
24 V DC / 0.5 A
Rated current control emergency power relay
0.5 A
Connection design
Screw terminals (10 mm²
cross-section)
Supply type
Single phase
Battery data