58300000187895 ARA EN A
MAY 2015
Service Manual for Bosch Benchmark Series Induction Slide-in Ranges
Page 31 of 36
Copyright by BSH Home Appliances Corporation
1901 Main St
▪ Suite 600 ▪ Irvine, CA 92614
800 944-2904
This material is intended for the sole use of BSH authorized persons and may contain confidential and proprietary information. Any unauthorized review, use, copying, disclosure, or distribution in any format is prohibited.
Error
Code
Description
Cause/Notes
Suggested Action(s)
E032
Continuous pushing of multiple
keys
(E432 internal error reported as
E032.)
Two or more keys continuously pressed for 10
seconds or touch pad assembly has more than
one bad key. Key actions are suspended and
heating is paused. Error will clear and normal
operation will resume when no touch pads are
depressed.
Confirm touch panel is clean and free of
moisture, oils or other contaminants.
Inspect user interface PCB.
Check door seal to verify vapor/moisture is
not causing key activation; replace seal if
necessary. Run Key Test in Service mode; if
it fails, replace front panel assembly.
E044
Touch control module (TCM)
option code error
TCM board or connections to TCM are bad.
During start-up, the control module is unable
to set TCM option code. Reset is required to
clear error.
Enter Service mode to set correct option
code.
Check connection to control module.
Check connection to TCM.
If unable to set option code and
connections are good, replace front panel
assembly.
E050
Rotary encoder switch short to
Vcc
A short to Vcc is detected in an encoder switch
for more than 10 seconds.
E101
E201
Cavity 1 / Cavity 2 temperature
sensor open
Temperature sensor disconnected or has a
faulty connection. Cooling fan will operate at
high speed and heating will stop. After two
consecutive temperature readings are made
successfully, heating will resume and error will
be cleared. See Communication Schematic.
Check all connections and wires to
temperature sensor.
Check resistance of temperature sensor: if
sensor tests OK, could be control module
problem; if sensor fails, replace sensor.
E104
E204
Cavity 1 / Cavity 2 temperature
sensor shorted
Temperature sensor shorted to ground.
Cooling fan will operate at high speed and
heating will stop. After two consecutive
temperature readings are made successfully,
heating will resume and error will be cleared.
See Communication Schematic.
Check wires and connections for pinch or
short circuit to ground.
Check resistance of temperature sensor: if
sensor tests OK, could be control module
problem; if sensor fails, replace sensor.