58300000187895 ARA EN A
MAY 2015
Service Manual for Bosch Benchmark Series Induction Slide-in Ranges
Page 19 of 36
Copyright by BSH Home Appliances Corporation
1901 Main St
▪ Suite 600 ▪ Irvine, CA 92614
800 944-2904
This material is intended for the sole use of BSH authorized persons and may contain confidential and proprietary information. Any unauthorized review, use, copying, disclosure, or distribution in any format is prohibited.
Figure 21 Display board secured to carrier with the carrier’s 4 metal tabs
Figure 19 Location of screws on control panel service assembly
which, if any, keys are activated. The response to a each key press is
controlled by the control module.
The complete control panel assembly is offered as the service
replacement for the skin, touch panel, and/or TCM. These
components are not available separately.
Also attached to the front panel assembly are the display board and
its sheet metal carrier. These parts are not actually included with the
front panel service assembly; the display must be ordered separately.
A Front Panel Test is available in Service mode. See the
Service
Mode
section for details.
7.4.1 Replacing the Control Panel Assembly
1. Remove power to the range.
2. Open oven door and remove three screws on the underside of
the control panel assembly – one on the right and one on the
left, and one screw from each side.
3. Grasping the panel on both sides, carefully pull it forward; the
user interface harness connected to the TCM and to the
display will limit how far away the control panel assembly can
be moved initially.
4. Disconnect the wires attached to the switches, the hot surface
indicator and the touch panel.
5. Remove knobs, grommets and switches.
6. Remove the four screws securing the sheet metal carrier to
the control panel assembly and set the carrier and display
board aside.
7. Install the carrier and display board to the new control panel
service assembly using the four screws removed in step 5.
8. Re-connect the user interface harness and switch wires, then
install the new control panel assembly.
9. Install the grommets and knobs.
10. Restore power and test operation.
7.4.2 Replacing the Display Module
The display module is secured to the sheet metal carrier with four
metal tabs.
Figure 20 Location of screws on sheet metal carrier