Error
Code
Description
Cause/Notes
Suggested Action(s)
E005
E305
Communication error
E005: Loss of communication between user
interface and control module.
E305: Loss of communication between TCM
and control module or TCM and user interface.
Check for damaged (cut or pinched) wires
or loose connectors.
Confirm that voltage is getting to the
correct pins on the board.
E009
E309
ROM-check error in user interface
ROM-check performed at reset fails. All
heating elements disabled. Error will be
cancelled at start-up if next ROM-check
succeeds.
E009: Replace user interface
E309: Replace control module
E010
E310
Data memory error in user
interface
Cyclic check of memory content or a write to
memory failed. All heating elements will be
disabled. Error will be cancelled at start-up.
E010: Replace user interface
E310: Replace control module
E011
Continuous pushing of a single key
(E411 internal error reported as
E011)
Key pressed continually for 10 seconds, or
touchpad assembly has a bad key. Heating will
be stopped and will resume when key is no
longer pressed.
Confirm touch panel is clean and free of
moisture, oils or other contaminants.
Inspect user interface PCB.
Check door seal to verify vapor/moisture is
not causing key activation; replace seal if
necessary. Run Key Test in Service mode; if
it fails, replace front panel assembly.
E303
Electronics Delta temperature too
high
Temperature sensor on the control module
detects temperature changes that, over time,
are higher than limit value. Control turns off
heating elements and fan defaults to high
speed. When cavity temperature reaches
212°F/100°C, heating will resume and error
will be cleared. (If self-clean was running, it will
be disabled until a control reset is performed.)
Check connections to cooling fan and to
control module (see Small Load Schematic).
Check element operation.
Check for air obstruction or damaged
upper/lower ventilation trims.
Check for stuck relays.
E312
Defective control module
temperature sensor
All oven operations suspended until control
reset.
Replace control module
E314
E414
Cancel
/
Off
key error
Oven operation will be stopped. Error
cancelled only by a system reset.
Check touch pad assembly.
Inspect user interface PCB.