7.3.1 Resetting and Replacing the HTC
Always troubleshoot a tripped HTC to determine the underlying cause
of the interruption.
To reset the HTC…
1. Remove power to the range.
2. Insert a flat blade screwdriver through one of the vent slots,
and depress the red reset button.
3. Restore power and test operation.
To remove the HTC from the front, a right-angled screwdriver will be
needed….
1. Remove power to the range.
2. First remove the latch plate and remove or slide the
latch/motor assembly aside as described in the
Replacing the
Latch/Motor Assembly
section.
3. Using a right-angled screwdriver, remove the two screws
securing the HTC to its mounting bracket.
4. Disconnect the wires and remove the HTC.
5. Install the new HTC.
6. Reinstall or reposition the latch motor assembly.
7. Reinstall all parts, reconnecting wires, as necessary (refer to
the
Service Guide
(wire diagram) attached to the rear vented
housing panel for reference.
8. Restore power and test operation.
7.4
Control Panel
The control panel service assembly includes…
Stainless front panel with gasket along inside bottom edge
Touch panel assembly: white LED touch panel assembly with
touch control module (TCM)
The TCM is an electronic module which monitors, qualifies, and
transmits the inputs from the touch panel to the control module. After
start-up, the control module polls the TCM every 100ms to determine
NOTICE
The HTC switch should only be reset once or twice before replacing.
The switch weakens each time it trips, so it will become easier and
easier for the switch to trip during high-temperature cycles (i.e., Self-
clean) if it has weakened over time.