Syslog
Server IP address
Enter the appropriate IP address of the server.
Server port (0 = Off)
Enter the number of the server port.
Protocol
Select the appropriate protocol:
UDP
,
TCP
, or
TLS
.
LLDP power configuration
Requested for camera
The value in this field identifies the number of watts requested for the camera.
Additional Power
Enter the number of additional watts that you want the camera to use.
Requested total
The value in this field is the total number of watts from the fields
Requested for camera
and
Additional Power
.
Allocated power
The value in this field is the number of watts of allocated power to the camera.
9.5
Network Management
SNMP
The camera supports the SNMP V1 (Simple Network Management Protocol) for managing and
monitoring network components, and can send SNMP messages (traps) to IP addresses. The
unit supports SNMP MIB II in the unified code. If you wish to send SNMP traps, enter the IP
addresses of one or two required target devices here.
If you select
On
for the
SNMP
parameter and do not enter an SNMP host address, the camera
does not send them automatically, but only replies to SNMP requests. If you enter one or two
SNMP host addresses, SNMP traps are sent automatically. Select
Off
to deactivate the SNMP
function.
1. SNMP host address / 2. SNMP host address
If you wish to send SNMP traps automatically, enter the IP addresses of one or two required
target units here.
SNMP traps
You can select which traps are to be sent.
1.
Click
Select
. A list is opened.
2.
Click the checkboxes to select the required traps. All the checked traps will be sent.
3.
Click
Set
to accept the selection.
UPnP
Select
On
to activate UPnP communication. Select
Off
to deactivate it.
When the Universal Plug-and-Play (UPnP) function is activated, the unit responds to requests
from the network and is automatically registered on the requesting computers as a new
network device. This function should not be used in large installations due to the large number
of registration notifications.
Note:
To use the UPnP function on a Windows computer, both the Universal Plug-and-Play Device
Host and the SSDP Discovery Service must be activated.
Summary of Contents for AUTODOME IP 4000i NDP-4502-Z12
Page 1: ...AUTODOME IP 4000i NDP 4502 Z12 NDP 4502 Z12C NDP 45A2 Z12C NDP 45A2 Z1 2CY en User Manual ...
Page 2: ......
Page 75: ...AUTODOME IP 4000i Troubleshooting 75 Bosch Security Systems User Manual 2020 06 2 0 ...
Page 76: ...76 Troubleshooting AUTODOME IP 4000i 2020 06 2 0 User Manual Bosch Security Systems ...
Page 77: ......