Communication Switch Setting
Communication Switch
The camera’s communication switches are specified in the table below.
Communication Switch
Switches
Description
SW1
RS-485 Setting
SW2
SW3
SW4
SW5
Reserved
SW6
Reserved
RS-485 Setting
The camera uses an RS-485 interface to communicate with the control device. For this reason,
the RS-485 setup of the camera and the control device must be the same. The default RS-485
setting is half-duplex. Do not change the default setting without any support from qualified
specialists or suppliers.
RS-485 Setting
Half-Duplex
Full-Duplex
ID Setting
If there is more than one camera in the same network, you must assign an ID number to each
camera. Access the OSD menu and go to <INSTALLER MENU>
→
<CAMERA ID SETTING>
→
<ID
SETTING> to assign the camera’s ID number. Refer to the section Camera Setting for detail
setting instructions.
Notice!
No two cameras in the same network should be given the same ID, or communication conflict
may occur.